Outback Power Systems manual Installing the FLEXnet DC, FLEXNet DC package includes

Page 8

The FLEXNet DC package includes:

A. FLEXnet DC

B. Ten-pin wiring plug for shunt, relay

C

D

 

 

and battery connections

 

 

 

 

C. Six feet of CAT5 cable for HUB connection

E

 

D. Ten-foot color-coded twisted pair

E

A

 

(TP) cable connects to the battery

 

 

E.

Three six-foot, color-coded,

 

 

 

twisted pair cables for shunt connections

 

 

F.

Two #6-32 X 3/8” panhead

 

B

 

machine screws

 

 

 

 

G. Colored labels identifying shunts

Installing the FLEXnet DC

The FLEXnet DC mounts in a 3/4” DC breaker slot in an OutBack DC breaker bracket installed inside a FLEXware enclosure or previous model OutBack enclosure. To mount the FLEXnet DC inside an OutBack enclosure:

1.Put the system into bypass mode

2.Shut off all AC input to inverters

3.Shut off all PV and DC breakers

4.Disconnect the battery cables at the battery

5.Remove the breaker bracket from its enclosure by removing the four corner screws

6.Remove a DC breaker knockout

FLEXnet DC mounts in a DC breaker slot after removing the breaker knockout

DC breakers off

PV breakers off

7

Image 8
Contents NetTM DC FLEXnet DC User’s Guide 2007 All rights reserved WarrantyAbout OutBack Power Systems Disclaimer Date and RevisionContact Information JanuaryTable of Contents OutBack Power Systems FLEXnet DC IntroductionSystem Overview Postion wiring block Reading the FLEXnet DCInstalling the FLEXnet DC FLEXNet DC package includesConnect each twisted pair to a shunt White to BAT Black to BAT + Wiring Block ConnectionsTorque Values Installing the FLEXnet DC Maximum battery voltage FLEXNet DC MeasurementsKiloWatts Maximum amp chargedData Logging User Adjustable Set PointsLogged Data Programming and Using the Mate for FLEXNet DC Operations All unused channels should be set to disabled FLEXNet DC ModesCharge Cycle Typical charge cycleGreen Yellow RED Auto Mode Programming the Auxiliary RelayRelay Logic Invert Logic Hi Set Point SatisfiedMate Screens Press the DC soft key to view the status of the FlexNet DC ReadingsDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the Charge soft key Press the ADV soft key Press the DC soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Battery Charge Factor BCF Technical NotesYear Limited Warranty FLEXnet ProductsRevision.2007-08-29 Limited Warranty Registration Outback Power Systems Inc 19009 62nd Ave. NEREV B