Outback Power Systems DC manual Mate Screens

Page 18

MATE Screens

MAIN

-------------------------------

From the MAIN MATE menu, press the <SUM> soft key

 

11:30:55A

to view a summary of the system’s operation.

SUM

STATUS

SETUP ADV

E

Battery Charging

F

This first summary screen appears for a few seconds

to display the battery State of Charge. The screen

 

automatically disappears and a system summary

State of charge 99%

screen appears.

 

DC NOW

12.5V

99%

Battery voltage

The current battery state-of-charge (SOC)

In

0.0A

0.000kW

Out

0.5A

0.000kW

In shows the amount of DC current coming into the

Bat

-0.5A

0.000kW

 

system from all sources

 

 

 

Out shows DC current from the system

 

 

 

Bat(tery) displays difference between the In and Out

 

 

 

 

values and shows whether the battery is storing or

 

 

 

 

 

 

 

 

using current

 

 

 

 

Press the second soft key to view the next SUM screen

 

 

 

 

(the screens will also scroll automatically after a user-

 

 

 

 

determined period of time programmed in the MATE).

DC Today

 

min/SOC 76%

• Minimum SOC today (since midnight)

In

347AH

9.040kWH

 

Out

331AH

8.510kWH

• In: Amp hours and kiloWatt hours from sources

Bat

 

16AH

0.530kWH

today

 

 

 

 

• Out: Amp hours and kiloWatt hours output by

 

 

 

 

Press to view

 

system today

Press to move

• Bat: Difference of battery in and out amp hours and

previous days’ history

 

 

 

forward one day

kiloWatt hours

Press the second soft key to view the next SUM screen

17

Image 18
Contents NetTM DC Warranty About OutBack Power SystemsFLEXnet DC User’s Guide 2007 All rights reserved Contact Information DisclaimerDate and Revision JanuaryTable of Contents OutBack Power Systems FLEXnet DC IntroductionSystem Overview Postion wiring block Reading the FLEXnet DCInstalling the FLEXnet DC FLEXNet DC package includesConnect each twisted pair to a shunt Wiring Block Connections Torque ValuesWhite to BAT Black to BAT + Installing the FLEXnet DC KiloWatts Maximum battery voltageFLEXNet DC Measurements Maximum amp chargedUser Adjustable Set Points Logged DataData Logging Programming and Using the Mate for FLEXNet DC Operations Charge Cycle All unused channels should be set to disabledFLEXNet DC Modes Typical charge cycleGreen Yellow RED Relay Logic Auto ModeProgramming the Auxiliary Relay Invert Logic Hi Set Point SatisfiedMate Screens Press the DC soft key to view the status of the FlexNet DC ReadingsDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the Charge soft key Press the ADV soft key Press the DC soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Battery Charge Factor BCF Technical NotesYear Limited Warranty FLEXnet ProductsRevision.2007-08-29 Limited Warranty Registration Outback Power Systems Inc 19009 62nd Ave. NEREV B