Outback Power Systems DC manual Logged Data, User Adjustable Set Points, Data Logging

Page 13

Logged Data*

The previous 128 days of data are accessible with the MATE. The data is logged each night at midnight. Be sure the MATE’s clock is set to the correct local time (refer to your MATE manual).

* Data Logging

User Adjustable Set Points

Battery charge factor (65-100%) [see page 29]

Battery bank capacity 0-10000 amp hours

Shunt A, B, C—enabled or disabled

Absorb volts (0-80.0 volts, the maximum voltage the battery can absorb)

Return amps (0-500.0A, the maximum current amperage going into the battery)

Parameters met timer (0-240 minutes, the amount of time allowed to recharge)

AUX Relay Set Points

Manual-On, Auto, Manual-Off—allows the user to turn the Aux Relay on and of like a manualf switch or to set it to Auto and have it function when certain conditions are met

Volts HI—when user determined high voltage value is met, the Aux activates

Volts LO—the Aux activates when a low voltage value is met

SOC (State-of-Charge) HI—a high state-of-charge activates the Aux

SOC (State-of-Charge) LO—a low state-of-charge activates the Aux

HI Delay—the user can adjust the high set point delay time (in minutes)

LO Delay—the user can adjust the low set point delay time (in minutes)

AUX-INVERT LOGIC—the invert logic function can be activated with a YES or NO command (see page 16)

12

Image 13
Contents NetTM DC About OutBack Power Systems WarrantyFLEXnet DC User’s Guide 2007 All rights reserved Date and Revision DisclaimerContact Information JanuaryTable of Contents Introduction OutBack Power Systems FLEXnet DCSystem Overview Reading the FLEXnet DC Postion wiring blockFLEXNet DC package includes Installing the FLEXnet DCConnect each twisted pair to a shunt Torque Values Wiring Block ConnectionsWhite to BAT Black to BAT + Installing the FLEXnet DC FLEXNet DC Measurements Maximum battery voltageKiloWatts Maximum amp chargedLogged Data User Adjustable Set PointsData Logging Programming and Using the Mate for FLEXNet DC Operations FLEXNet DC Modes All unused channels should be set to disabledCharge Cycle Typical charge cycleGreen Yellow RED Programming the Auxiliary Relay Auto ModeRelay Logic Invert Logic Hi Set Point SatisfiedMate Screens Readings Press the DC soft key to view the status of the FlexNet DCDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the ADV soft key Press the DC soft key Press the Charge soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Technical Notes Battery Charge Factor BCFFLEXnet Products Year Limited WarrantyRevision.2007-08-29 Outback Power Systems Inc 19009 62nd Ave. NE Limited Warranty RegistrationREV B