Outback Power Systems DC manual Down Status

Page 20

A:0.1A 0.000 kW

B:0.0A 0.000 kW

C:0.0A 0.000 kW

DOWN STATUS

A:

-1AH

0.100kWH

B:

0AH

0.000kWH

C:

0AH

0.O00kWH

DOWN

UP

TOP

METER/DC/SHUNT A removed

12AH 0.030kWH

DOWN UP TOP

METER/DC/SHUNT A charged

12AH 0.160kWH

DOWN UP TOP

The first METER screen shows the amount of instantaneous current running through each shunt. A positive value indicates current flow into the battery; a negative value means a load is being supplied. Press the <DOWN> soft key to view the AH and kWH (amp hour and watt hour) screen.

The second METER screen shows the accumulated amp hours and kilowatt hours for each shunt. Press the <DOWN> soft key to view the next METER screen.

This screen shows the number of removed amp hours and watt hours as measured by SHUNT A. Press the <DOWN> soft key to view the SHUNT A charged screen.

The fourth meter screen displays the number of charged amp hours and watt hours as measured by SHUNT A. Press the <DOWN> soft key to view the first SHUNT B METER screen.

METER/DC/SHUNT B removed

AH 0kWH

DOWN UP TOP

METER/DC/SHUNT B charged

AH 0kWH

DOWN UP TOP

Pressing the <DOWN> soft key brings up the SHUNT B charged screen.

Pressing the <DOWN> soft key brings up the first SHUNT C METER screen.

19

Image 20
Contents NetTM DC FLEXnet DC User’s Guide 2007 All rights reserved WarrantyAbout OutBack Power Systems Disclaimer Date and RevisionContact Information JanuaryTable of Contents OutBack Power Systems FLEXnet DC IntroductionSystem Overview Postion wiring block Reading the FLEXnet DCInstalling the FLEXnet DC FLEXNet DC package includesConnect each twisted pair to a shunt White to BAT Black to BAT + Wiring Block ConnectionsTorque Values Installing the FLEXnet DC Maximum battery voltage FLEXNet DC MeasurementsKiloWatts Maximum amp chargedData Logging User Adjustable Set PointsLogged Data Programming and Using the Mate for FLEXNet DC Operations All unused channels should be set to disabled FLEXNet DC ModesCharge Cycle Typical charge cycleGreen Yellow RED Auto Mode Programming the Auxiliary RelayRelay Logic Invert Logic Hi Set Point SatisfiedMate Screens Press the DC soft key to view the status of the FlexNet DC ReadingsDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the Charge soft key Press the ADV soft key Press the DC soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Battery Charge Factor BCF Technical NotesYear Limited Warranty FLEXnet ProductsRevision.2007-08-29 Limited Warranty Registration Outback Power Systems Inc 19009 62nd Ave. NEREV B