Avery 206 Electronics, Internal Interfaces, Status messages, test functions, product profiles

Page 19

CONTENTS

2.1OVERVIEW

Electronics

Processor:

32 Bit CPU MIPS Core

 

 

RAM:

16 MB

 

 

ROM:

4 MB

 

 

Control panel:

graphical display with

 

128 x 32 pixels, 2/4 lines,

 

5 buttons

 

 

Interfaces

Sensor interfaces for

(plug in each case 4-

external sensors

pin M12)

Label sensor:

Wenglor OPT242-P800

 

optical, NPN, 24 V, con-

 

trollable sensitivity

Alternative label

PNP/NPN, 24 V

sensor:

 

Product sensor:

PNP/NPN, 24 V

APSF-sensor (Rotary

single-phase/two-phase,

encoder):

PNP/P-P, 24 V, max.

 

20 kHz

Stock sensor:

PNP, 24 V

 

 

Internal sensor interfac-

 

es:

 

Material unwinder

Light barrier

Pressure roller

not used

Dancer arm

bi-phase light barrier en-

 

coder

 

 

PLC interface

Sub D15, optically insu-

 

lated, optionally via two

 

8-pin M12 (separate in-

 

puts/outputs in each

 

case)

Outputs:

4x PNP, 24 V, a maxi-

 

mum of 500 mA/channel,

 

total permissible output

 

current: 1500 mA

Inputs:

3x PNP/NPN, 24 V

 

 

ALS 20x 256

GB

Data interfaces:

 

Serial:

RS232C (Sub-D9),

 

max. 115 200 Baud

Ethernet:

10/100 BaseT (RJ45)

USB:

Device V1.1 (USB B),

 

‘Full speed’ operating

 

mode, 12 MBit/s

CF card:

Slot for 1 CompactFlash

 

card

Control panel

RS 485 (Mini DIN 6 con-

interface:

nection) for remote con-

 

trol

 

 

Internal Interfaces

RFID

Connection for RFID

 

read/write unit (special

 

equipement) 6)

Applicator Interface

Connection for Applicator

 

Interface (AI) board (spe-

 

cial equipement)

 

 

Connector for additional

not used

motor driver

 

 

 

6) Not yet available

 

Status messages, test functions, product profiles

Automatic halt, if

... the label roll is spent or

 

no gap was found.

 

...the max. admissible

 

number of missing labels

 

is reached.

 

 

Test functions:

Automatic diagnostics

 

check when switched on

 

Output of system data via

 

data interface

 

 

Status indicators:

Label counter

 

Operating hours counter

 

 

Storage locations for

up to 16

product profiles:

 

 

 

15

Image 19
Contents 204/206 256 Page Product description Please noteOperational failures Before operationAfter operation OperationValidity and binding effect of this manual General NotesParameters Signs and symbolsButton symbols Illustrations and descriptionsKeep the product information at hand Safety InstructionsInformation and qualifications Follow the instructionsProper usage Operational safety of the unitProtection against injuries by electrical current Protection against injuries by chemicals Protection against injuries by mechanical actionDue diligence of the user Before beginning productionPinch point Safety notes on the unitComponents OverviewALS 20x LCD display Error LEDControl panel Operating LEDConnections on the back of the device Connection arrangementLabel Label H Sensor connectionsMode of operation Labels Technical specificationsCharacteristics Power supplyStatus messages, test functions, product profiles ElectronicsInterfaces Internal InterfacesCertificates DimensionsEnvironmental conditions IntegrationRight-handed version Design modelsLeft-handed version Swivelling dispensing edge OptionsExternal control panel Fixed dispensing edgePneumatic dispensing edge Adjustable dispensing edge holderShape dispensing edge Applicator interface Outer Diameter control sensorPrinter ApplicatorOperating Modes Dispensing modeDispensing speed Online settingsFunction of the double-arrow button Configuration modeMenus German FunctionsFunction overview Function DescriptionsSERVICE/DIAGNOS Service Data Machine Setup menu Label Setup menuService Data menu Electrical Connections Power supply connectionConnecting the power cable Checking the power supply settingSwitch setting Permissible mains voltage C D Connecting sensorsPrerequisites ALSRemoving glue residue Inserting Label MaterialInserting a label roll Removing spent backing paperThreading guide Threading the label rollThreading the label roll at the dispensing edge Fastening the label roll to the rewinder Threading the label roll onto the drive rollerAdjusting the unwinder’s core diameter Mechanical SettingsPositioning the pressure roller Positioning the label sensor Dispensing with a product sensor START-UP and ShutdownTurning on the unit Starting label dispensingStopping the dispensing process Label stop position Configuration and MonitoringFunction menu settings Label pitchDispensing speed Configuring speed adaptionLabel position on the product 256Material end Monitoring functionsMaterial tear Missing labelsStoring a product profile Using Product ProfilesWhat are product profiles? Loading a product profileDeleting a product profile Call the Machine Setup Del. prod.profil functionActive fuse Mains voltage Switch setting Maintenance and CleaningReplacing fuses Cleaning agents Removing paper debris Regular maintenanceRenewal of the dust filter liner ALS Status Status text Cause Error MessagesReporting errors List of error messagesALS 20x Set to Dhcp Interface Para EU Declaration of Conformity Avery Dennison Deutschland GmbH