4.2CONFIGURATION AND MONITORING

ALS 20x 256

GB

4.2.1Function menu settings

Label pitch

Switch to configuration mode

Calibrating the label pitch automatically:

Hold down the button for a while (longer than two seconds).

Or: Enter the label pitch manually: Measure the label pitch [45C].

Call the LABEL SETUP > Label pitch function. Enter the measured value in millimetres.

Label stop position

Prerequisites:

– The label length must be specified.

The next label to be dispensed waits in the label stop position. Here it is useful if the label protrudes over the dispensing edge a little [46].

ALS 20X and ALS 256 labellers are pre- configured for use with the supplied label sensor. If this sensor is employed, the label stop position setting will only require minimal correction.

Correcting the default setting:

Call the LABEL SETUP > Lab. stop offset function. Increase the value to increase the overhang or lower the value to reduce the overhang.

The value ‘0’ will cause the label to stop with its front edge directly under the label sensor.

The front edge of the next label to be dispensed should be flush with the dispensing edge:

Enter the distance [46A] between the label sensor and the dispensing edge.

The front edge of the label to be dispensed should overhang:

Add the length of the overhang to the distance between the label sensor and the dispensing edge.

A

B

C

 

[45]A Label web B Label

C Label pitch

A

[46] Label stop position (A)

41

Image 45
Contents 204/206 256 Page Product description Please noteAfter operation Before operationOperation Operational failuresValidity and binding effect of this manual General NotesButton symbols Signs and symbolsIllustrations and descriptions ParametersInformation and qualifications Safety InstructionsFollow the instructions Keep the product information at handOperational safety of the unit Proper usageProtection against injuries by electrical current Protection against injuries by chemicals Protection against injuries by mechanical actionDue diligence of the user Before beginning productionPinch point Safety notes on the unitComponents OverviewALS 20x Control panel Error LEDOperating LED LCD displayConnections on the back of the device Connection arrangementLabel Label H Sensor connectionsMode of operation Characteristics Technical specificationsPower supply LabelsInterfaces ElectronicsInternal Interfaces Status messages, test functions, product profilesEnvironmental conditions DimensionsIntegration CertificatesDesign models Right-handed versionLeft-handed version External control panel OptionsFixed dispensing edge Swivelling dispensing edgeAdjustable dispensing edge holder Pneumatic dispensing edgeShape dispensing edge Printer Outer Diameter control sensorApplicator Applicator interfaceOperating Modes Dispensing modeDispensing speed Online settingsConfiguration mode Function of the double-arrow buttonMenus German FunctionsFunction overview Function DescriptionsSERVICE/DIAGNOS Service Data Machine Setup menu Label Setup menuService Data menu Electrical Connections Power supply connectionChecking the power supply setting Connecting the power cableSwitch setting Permissible mains voltage C D Connecting sensorsPrerequisites ALSInserting a label roll Inserting Label MaterialRemoving spent backing paper Removing glue residueThreading guide Threading the label rollThreading the label roll at the dispensing edge Fastening the label roll to the rewinder Threading the label roll onto the drive rollerMechanical Settings Adjusting the unwinder’s core diameterPositioning the pressure roller Positioning the label sensor Turning on the unit START-UP and ShutdownStarting label dispensing Dispensing with a product sensorStopping the dispensing process Function menu settings Configuration and MonitoringLabel pitch Label stop positionDispensing speed Configuring speed adaptionLabel position on the product 256Material tear Monitoring functionsMissing labels Material endWhat are product profiles? Using Product ProfilesLoading a product profile Storing a product profileDeleting a product profile Call the Machine Setup Del. prod.profil functionMaintenance and Cleaning Active fuse Mains voltage Switch settingReplacing fuses Cleaning agents Regular maintenance Removing paper debrisRenewal of the dust filter liner ALS Reporting errors Error MessagesList of error messages Status Status text CauseALS 20x Set to Dhcp Interface Para EU Declaration of Conformity Avery Dennison Deutschland GmbH