Avery 204 Maintenance and Cleaning, Replacing fuses, Active fuse Mains voltage Switch setting

Page 51

CONTENTS

5.1MAINTENANCE AND CLEANING

ALS 20x 256

GB

5.1.1Replacing fuses

This section counts only for ALS 20X. The fu- ses at the ALS 256 cannot be replaced.

WARNING!

The machine operates using mains voltage! Touching live electrical parts may expose you to hazardous electrical currents and may lead to burns.

Make sure that the machine is switched off and the power cable is unplugged before removing the fuse insert.

CAUTION!

Risk of fire, if a wrong fuse type is inserted. Only replace fuses with the type and rating specified in this manual.

The F1 and F2 fuses protect the primary side of the transformer. At any given time, only one of the two fuses is active. Which fuse is active depends on the switch setting of the voltage selector switch.

Active fuse

Mains voltage

Switch setting

 

 

 

F1

230 V

230

 

 

 

F2

110 V

115

[49]Relation between the switch setting of the voltage selector switch and the active fuse.

Tool: Screwdriver

Turn off the unit. Unplug the power cable.

Rotate the fuse holder a few degrees anticlockwise.

The fuse holder pops up.

Take the fuse out of the fuse holder. Replace defective fuse.

Replace the fuse holder and rotate it clockwise, while applying light pressure, until the slot is vertically positioned.

Required fuse type:

– T5AH 250 V

A

[50] Fuse holder (A) of the ALS 20x.

The CPU board and sensors are protected by a separate fuse in the switching power supply that must/may never be replaced.

If either of the two fuses is not working properly, only the drive motors are affected; the display and sensors continue to operate as normal.

47

Image 51
Contents 204/206 256 Page Product description Please noteOperational failures Before operationAfter operation OperationValidity and binding effect of this manual General NotesParameters Signs and symbolsButton symbols Illustrations and descriptionsKeep the product information at hand Safety InstructionsInformation and qualifications Follow the instructionsOperational safety of the unit Proper usageProtection against injuries by electrical current Protection against injuries by chemicals Protection against injuries by mechanical actionDue diligence of the user Before beginning productionPinch point Safety notes on the unitComponents OverviewALS 20x LCD display Error LEDControl panel Operating LEDConnections on the back of the device Connection arrangementLabel Label H Sensor connectionsMode of operation Labels Technical specificationsCharacteristics Power supplyStatus messages, test functions, product profiles ElectronicsInterfaces Internal InterfacesCertificates DimensionsEnvironmental conditions IntegrationDesign models Right-handed versionLeft-handed version Swivelling dispensing edge OptionsExternal control panel Fixed dispensing edgeAdjustable dispensing edge holder Pneumatic dispensing edgeShape dispensing edge Applicator interface Outer Diameter control sensorPrinter ApplicatorOperating Modes Dispensing modeDispensing speed Online settingsConfiguration mode Function of the double-arrow buttonMenus German FunctionsFunction overview Function DescriptionsSERVICE/DIAGNOS Service Data Machine Setup menu Label Setup menuService Data menu Electrical Connections Power supply connectionChecking the power supply setting Connecting the power cableSwitch setting Permissible mains voltage C D Connecting sensorsPrerequisites ALSRemoving glue residue Inserting Label MaterialInserting a label roll Removing spent backing paperThreading guide Threading the label rollThreading the label roll at the dispensing edge Fastening the label roll to the rewinder Threading the label roll onto the drive rollerMechanical Settings Adjusting the unwinder’s core diameterPositioning the pressure roller Positioning the label sensor Dispensing with a product sensor START-UP and ShutdownTurning on the unit Starting label dispensingStopping the dispensing process Label stop position Configuration and MonitoringFunction menu settings Label pitchDispensing speed Configuring speed adaptionLabel position on the product 256Material end Monitoring functionsMaterial tear Missing labelsStoring a product profile Using Product ProfilesWhat are product profiles? Loading a product profileDeleting a product profile Call the Machine Setup Del. prod.profil functionMaintenance and Cleaning Active fuse Mains voltage Switch settingReplacing fuses Cleaning agents Regular maintenance Removing paper debrisRenewal of the dust filter liner ALS Status Status text Cause Error MessagesReporting errors List of error messagesALS 20x Set to Dhcp Interface Para EU Declaration of Conformity Avery Dennison Deutschland GmbH