Avery 256, 204, 206 manual Set to Dhcp Interface Para

Page 56

CONTENTS

6.1ERROR MESSAGES

ALS 20x 256

GB

Status Status text

Cause

Action to take

5147 Tandemsynch. Init

This message can only appear

 

during tandem operation.

Communication between the master and slave machines is not function- ing.

Check tandem interface cable.

Is it a) in place and b) correctly con- nected?

Check the settings on both ma- chines.

Siehe “Setting up tandem operation” auf Seite 112.

5200

Home position

 

This message may appear when

 

 

 

 

 

 

operating the applicator. The ap-

 

 

 

 

plicator did not reach its home

 

 

 

 

position (upper end position)

Remove any obstructions

 

 

 

within the intended time-frame.

 

 

– The applicator is stuck

Check compressed air connection

 

 

and reconnect correctly if necessary

 

 

– Compressed air applicator: Com-

 

 

Check cable and connect correctly if

 

 

pressed air supply interrupted or

 

 

necessary.

 

 

switched off

 

 

 

 

 

– Cable not correctly connected.

 

 

 

 

 

 

5201

Touch Down

The applicator lower end position

 

 

 

(Touch Down) was not reached in time.

 

 

 

 

 

 

6002

New prog. vers.

New firmware has been loaded. This is a

Press the Online button to confirm.

 

 

message from the labeller that new

– All parameters are reset to their fac-

 

 

firmware is available.

tory settings.

 

 

 

 

 

6031

New Parameters

New firmware was loaded with the result

No action necessary. The message

 

 

that new functions have been added to

 

 

is for information only.

 

 

the menu.

 

 

 

 

 

 

 

 

6207

No file card

No compact flash card was found.

Check whether a compact flash card

 

 

 

 

is connected. If the compact flash

 

 

 

 

card was not connected until after the

machine was switched on: Switch the machine off and back on again.

9022 No network link

This status message can only appear

 

when Ethernet address assignment is

 

set to DHCP (INTERFACE PARA >

 

NETWORK PARAM.> IP Addressassign). The

 

cause is almost invariably an incorrectly

 

plugged-in network connector.

Check whether the network connec- tor is plugged in correctly, correct if necessary.

[53] List of error messages

52

Image 56
Contents 204/206 256 Page Please note Product descriptionBefore operation After operationOperation Operational failuresGeneral Notes Validity and binding effect of this manualSigns and symbols Button symbolsIllustrations and descriptions ParametersSafety Instructions Information and qualificationsFollow the instructions Keep the product information at handProtection against injuries by electrical current Operational safety of the unitProper usage Protection against injuries by mechanical action Protection against injuries by chemicalsBefore beginning production Due diligence of the userSafety notes on the unit Pinch pointOverview ComponentsALS 20x Error LED Control panelOperating LED LCD displayConnection arrangement Connections on the back of the deviceSensor connections Label Label HMode of operation Technical specifications CharacteristicsPower supply LabelsElectronics InterfacesInternal Interfaces Status messages, test functions, product profilesDimensions Environmental conditionsIntegration CertificatesLeft-handed version Design modelsRight-handed version Options External control panelFixed dispensing edge Swivelling dispensing edgeShape dispensing edge Adjustable dispensing edge holderPneumatic dispensing edge Outer Diameter control sensor PrinterApplicator Applicator interfaceDispensing mode Operating ModesOnline settings Dispensing speedMenus Configuration modeFunction of the double-arrow button Functions GermanFunction Descriptions Function overviewSERVICE/DIAGNOS Service Data Label Setup menu Machine Setup menuService Data menu Power supply connection Electrical ConnectionsSwitch setting Permissible mains voltage Checking the power supply settingConnecting the power cable Connecting sensors C DALS PrerequisitesInserting Label Material Inserting a label rollRemoving spent backing paper Removing glue residueThreading the label roll Threading guideThreading the label roll at the dispensing edge Threading the label roll onto the drive roller Fastening the label roll to the rewinderPositioning the pressure roller Mechanical SettingsAdjusting the unwinder’s core diameter Positioning the label sensor START-UP and Shutdown Turning on the unitStarting label dispensing Dispensing with a product sensorStopping the dispensing process Configuration and Monitoring Function menu settingsLabel pitch Label stop positionConfiguring speed adaption Dispensing speed256 Label position on the productMonitoring functions Material tearMissing labels Material endUsing Product Profiles What are product profiles?Loading a product profile Storing a product profileCall the Machine Setup Del. prod.profil function Deleting a product profileReplacing fuses Maintenance and CleaningActive fuse Mains voltage Switch setting Cleaning agents Renewal of the dust filter liner ALS Regular maintenanceRemoving paper debris Error Messages Reporting errorsList of error messages Status Status text CauseALS 20x Set to Dhcp Interface Para EU Declaration of Conformity Avery Dennison Deutschland GmbH