Panamax MB1000 manual RS-232 Communications Protocol & Command Set, To program IR output

Page 9

Advanced Operation

2.If the delay settings are the same for both IR1 and IR2, the IR2 code will be sent to both outputs 2 seconds after IR1.

3.The IR commands will also be transmitted immediately after the battery charge falls below the critical load battery threshold. This ensures that equipment will be shutdown properly if the UPS’s load level is extremely high and the backup time would be less than the selected IR output delay.

4.There is no IR output after the power is restored to the system.

To program IR output:

1.From the setup menu, turn the Menu Navigation Knob until IR1 Setup is displayed. Push the Menu Navigation Knob to select.

2.Turn the Menu Navigation Knob until IR1 Program is dis- played.

3. The screen will display the message “READY TO SAMPLE REMOTE”. Press the button on the remote.

4.If the signal was learned, then the screen will display the message “IR1 SAMPLED” and advance to the “TEST IR” screen. Press the navigation knob to test.

5.If the signal was not learned, the screen will display the mes- sage “IR1 SAMPLE FAIL”, then it will return to the IR1 Program screen. Repeat steps 3 and 4.

6.To program another IR device, from the Setup menu, turn the Menu Navigation Knob until IR2 Setup is displayed. Follow steps 3-5.

RS-232 Communications Protocol & Command Set

RS-232 Control with Open Protocol

The RS-232 serial interface can be used in the following ways:

1.Initial system setup. An installer can use a notebook comput- er to set the variables within the Power Control software. Once the setup is completed, the notebook computer can be discon- nected. All settings are stored in the UPS.

2.Connection to a PC or Network: Functionality is very similar to a standard UPS with a PC.

The UPS can provide continued power to maintain recording capabilities of any number of devices in the event of a black out or brown out. It is also capable of saving open documents and shutting down the PC during extended power failures. This re- quires a permanent RS232 connection to the PC and having the Power Control software running in the background on the PC. (Windows based OS only; Mac Energy Saver software compat- ible)

3.Integration with sophisticated automation systems like AMX and Crestron:

The serial communications command set and protocol is open and is published later in this manual. This information can be used by the automation system programmer for both UPS control by the automation system and reporting of power events by the UPS to the automation system.

7

Image 9
Contents MB1000 Instructions FeaturesBefore You Begin Unpacking Inspect the UPS upon receipt Table of ContentsBattery replacement recommended every two years Important Safety InstructionsAC Power Installing Your UPSInput UPS OutputBasic Operation Front Panel Description Power SwitchOperating Modes Setup Mode Flowchart Advanced Operation To program IR output RS-232 Communications Protocol & Command SetRS-232 Control with Open Protocol RS-232 serial interface can be used in the following waysCommunications Protocol Controller CommandsALL on ALL OFFSwitch Outlet Bank SET Buzzer ModeSET Bank 2 Threshold SET Feedback Mode SET AVR ModeSET Linefeed Mode SET Display Sleep ModePower Status Reset Factory SettingsQueries Identify Outlet StatusList Configuration Battery Level StatusPower Button Status Change Condition Response Power Fault Status Change Condition ResponseFCC Notice and Warranties Limited Product WarrantyCaractéristiques Table des matières Avant de commencerUn câble USB Les dispositifs fournis par PF Power ne sont pas destinés Ne tentez pas le remplacement de la batteriePour votre sécurité Alimentation Installation de votre onduleurAlimentation c. a Sortie onduleurInterrupteur Manœuvres de base Description DU Panneau FrontalModes de fonctionnement IR1 Test IR1 Program IR1 Sample Fail Manœuvres complexes Protocole de communication et jeu de commandes RS-232 Pour programmer les émissions infrarougesContrôle RS-232 avec protocole libre Protocole de communication Commandes de contrôleActivation Générale Désactivation GénéraleConfigurer LE Seuil Plancher DU Bloc Configurer LE Mode DE Signal D’ALARMEBasculer UN Bloc DE Prises Configurer LE Mode DE Réponse Configurer LE Mode DE Régulation Automatique DE LA TensionConfigurer LE Mode Saut DE Ligne Configurer LA LuminositéÉtat DES Prises Requêtes IdentificationÉtat DU Courant TensionsCharge DE LA Batterie Liste DES ConfigurationsChangement D’ÉTAT DE L’INTERRUPTEUR Condition Réponse Changement D’ÉTAT DU Courant Condition RéponseAvertissement Avis FCC et garantiesCaracterísticas MB1000 InstruccionesTabla de contenido Págs , 9, 10, 11Cable USB ¡IMPORTANTE Instrucciones de seguridad importantesEntrada Instalación del suministro de energía ininterrumpible UPSCorriente alterna Salida de UPSInfrarroja IR Operación básica Descripción DEL Panel FrontalModos de operación IR1 Test IR1 Program IR1 Sample Fail Operación avanzada Para programar la salida IR Protocolo de comunicaciones RS-232 y conjunto de comandosComandos del controlador Protocolo de comunicacionesEncender Todo Apagar TodoConfigurar Umbral DE Regleta Configurar Modo DE ZumbadorConmutar Regleta Configurar Modo DE Realimentación Configurar Modo AVRConfigurar Modo DE Salto DE Línea Configurar Brillo DEL MedidorEstado DE Regletas Consultas IdentificaciónEstado DE Alimentación VoltajeEstado DE Nivel DE Batería Listar ConfiguraciónCambio DE Estado DE Regleta Condition ResponseNotificación de la FCC y garantías Notificación de la FCCGarantía de dos años de la batería

MB1000 specifications

The Panamax MB1000 is a prominent addition to the maritime industry, recognized for its advanced features and capabilities that cater specifically to the transportation and cargo handling sectors. Designed with a focus on efficiency and performance, this vessel has become a preferred choice among shipping companies looking to optimize their operations.

One of the main characteristics of the MB1000 is its impressive cargo capacity. With a deadweight tonnage exceeding 60,000 tons, the vessel is engineered to carry a significant amount of cargo, making it an ideal solution for bulk carriers. This capacity is coupled with a well-designed hull that ensures stability and speed, allowing for quick turnarounds and efficient voyages.

The MB1000 is equipped with state-of-the-art propulsion technology. It features a powerful diesel engine that delivers high output while maintaining fuel efficiency. The combination of low fuel consumption and reduced emissions aligns with global environmental standards, making the MB1000 a more eco-friendly choice in the industry.

In terms of navigation and safety, the vessel is outfitted with advanced electronic systems. The integrated bridge system includes radar, GPS, and autopilot functions that enhance situational awareness for the crew, ensuring safer and more precise navigation across various maritime conditions. Furthermore, the vessel adheres to the latest safety regulations, equipped with life-saving equipment and fire-fighting systems to ensure the utmost safety for the crew and cargo.

The design of the MB1000 also emphasizes crew comfort and operational efficiency. The ship features spacious accommodations, including well-appointed cabins and common areas designed to provide a restful environment during long voyages. The operational areas are meticulously arranged to facilitate smooth workflows for the crew, improving overall productivity.

Additionally, the Panamax MB1000 is built for adaptability, enabling shipping companies to adjust the interior layouts and equipment based on specific cargo requirements. This flexibility, combined with cutting-edge engineering and innovative technologies, solidifies the MB1000’s reputation as a modern workhorse in the maritime sector.

Overall, the Panamax MB1000 stands out as a sophisticated vessel that encapsulates the evolution of maritime technology, combining performance, safety, and environmental consciousness, making it a valuable asset for any shipping fleet.