HUAWEI MG323 GSM M2M Module
AT Command Interface Specification Commands for Network Services
Issue 02 (2010-11-23) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd. 106
<index2>: end sequence number in the list of preferred operators. The value of
<index2> must be larger than that of <index1>. Otherwise, the ERROR is returned.
<oper>: indicates an operator name in numeric format.

8.12.3 Examples

Example:
Read the current range of preferred operators.
AT^SPLR=1,2
^SPLR:1.“46000”
^SPLR:2.“46001”
OK
8.13 AT^SPLW - Command for Writing Preferred Operators
The AT^SPLW command writes preferred operators.

8.13.1 Checking the Parameter Range Supported by This

Command

Test
command
AT^SPLW=?
Function Returns the parameter range supported by this command.
Response z In case of successful execution:
<CR><LF>^SPLW: (list of supported <index>s) <CR><LF>
<CR><LF>OK<CR><LF>
z In case of an error during command execution:
<CR><LF>ERROR<CR><LF>
z In case of an error related to the MT during command execution:
<CR><LF>+CME ERROR: <err><CR><LF>
Parameter description
<index>: sequence number of location