HUAWEI MG323 GSM M2M Module

 

AT Command Interface Specification

Commands for Data Services

9.6.3 Examples

Example:

Define the PDP context.

AT+CGDCONT=1,“IP”,“1234”

OK

Activate the PDP context.

AT+CGACT=1,1

OK

Read the PDP address. AT+CGPADDR=1 +CGPADDR:1,“192.168.50.64”

OK

9.7AT+CGQMIN - Command for Setting the Acceptable Minimum Quality of Service Profile

The AT+CGQMIN command allows the TE to specify an acceptable minimum quality of service (QoS). This profile is verified by the MT and is compared with the negotiation profile returned by the “PDP context activation” message.

The write command can specify a profile for the context. This profile is identified by the (local) context identification parameter <cid>. If AT+CGQMIN= <cid> is sent, the defined QoS of <cid> is deleted.