HUAWEI MG323 GSM M2M Module
AT Command Interface Specification Commands for Serial Port Control
Issue 02 (2010-11-23) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd. 39
Parameter description
<value>: integer; AT&S is equivalent to AT&S 0.
z 0 (default value): The DSR is always valid.
z 1: When the ME is in command mode, the DSR is invalid. When the ME is in
data mode, the DSR is valid.
4.5 AT+IPR - Command for Setting the Baud Rate of the DTE-DCE
The AT+I PR command sets the baud rate of the DTE-DCE.

4.5.1 Querying the Supported Baud Rates of the DTE-DCE

Test
command
AT+IPR=?
Function Queries the supported baud rates of the DTE-DCE.
Response <CR><LF>+IPR: (list of supported auto-detectable <rate>s)[,(list of
supported fixed-only <rate>s)]<CR><LF>
<CR><LF>OK<CR><LF>
Parameter description
<rate>: integer, which is saved upon power failure.
0: indicates adaptive baud rate.
Range of baud rate adaptation: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and
115200.
Fixed baud rate: 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600,
115200, and 230400.
Default value: 115200.

4.5.2 Reading the Current Baud Rate of the DTE-DCE

Read
command
AT+IPR?
Function Reads the current baud rate of the DTE-DCE.
Response <CR><LF>+IPR: <rate><CR><LF>
<CR><LF>OK<CR><LF>