HUAWEI MG323 GSM M2M Module
AT Command Interface Specification Other Commands
Issue 02 (2010-11-23) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd. 209
ATS5 =8
OK
16.5 ^THERM - Command for Unsolicitedly Reporting Temperature Protection
The ^THERM command is used to unsolicitedly report the temperature protection.
The URC cannot be disabled currently.
URC <CR><LF>^THERM: <mode><CR><LF>
Note:
The temperature protection report is submitted automatically when the RF is enabled or
disabled by the temperature protection function.
Parameter description
<mode>: indicates the action performed by the current temperature protection
function.
z 0: indicates that the temperature exceeds the temperature limit and that the
module deregisters with the network and disables the RF.
z 1: indicates that the temperature falls back to the safe temperature range and
the module enables the RF.