HUAWEI MG323 GSM M2M Module
AT Command Interface Specification Commands for Network Services
Issue 02 (2010-11-23) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd. 92
8.8.1 Checking the Parameter Range Supported by This Command
Test command AT^MONP=?
Function Returns the parameter range supported by this command.
Response z In case of successful execution:
<CR><LF>^MONP: (list of supported <period>s)<CR><LF>
<CR><LF>OK<CR><LF>
z In case of an error during command execution:
<CR><LF>ERROR<CR><LF>
z In case of an error related to the MT during command
execution: <CR><LF>+CME ERROR: <err><CR><LF>
Parameter description
<period>: integer parameter, which indicates the period in seconds. Value range: 1–
254.
For details about other parameters, see the AT^SMONC command.