7.16.2 Reading the Settings of the CLIP Service
Read
command
AT+CLIP?
Function Reads the settings of the CLIP service.
Response z In case of successful execution:<CR><LF>+CLIP:
<n>,<m><CR><LF>
<CR><LF>OK<CR><LF>
z In case of an error: <CR><LF>ERROR<CR><LF>
Parameter description
<m>: integer; sets whether the CLIP service is provisioned on the network.
z 0: indicates that the CLIP is not provisioned.
z 1: indicates that the CLIP is provisioned.
z 2: unkown (due to interworking problems or limitations of originating network).
7.16.3 Setting the CLIP
Write
command
AT+CLIP=[<n>]
Function Enables or disables the CLIP service.
Response z In case of successful execution: <CR><LF>OK<CR><LF>
z In case of an error: <CR><LF>ERROR<CR><LF>
z In case of an error related to the MT: <CR><LF> +CME
ERROR: <err><CR><LF>
Note:
AT+C LIP = is equivalent to AT +CL IP= 0.
7.16.4 +CLIP - Command for Unsolicitedly Reporting the CLI
URC <CR><LF>+CLIP:
<number>,<type>[,<subaddr>,<satype>[,[<alpha>][,<CLI
validity>]]]<CR><LF>
Parameter description
<number>: character type, which indicates the telephone number.
<type>: integer type, which indicates the telephone number in character type.
z 145: international number