HUAWEI MG323 GSM M2M Module

 

AT Command Interface Specification

Overall Description

 

 

 

 

 

 

Command

Command Format

Description

 

Type

 

 

 

 

 

Read

<name>?

A read command is

 

 

command

 

executed to read the

 

 

 

 

current value of a

 

 

 

 

parameter.

 

 

 

 

 

 

 

Test

<name>=?

A test command is

 

 

command

 

executed to check the

 

 

 

 

parameter range.

 

 

 

 

 

 

 

 

Note:

 

 

 

 

If the MS fails to identify <name>, the MS returns ERROR. If the

 

 

 

MS can identify <name> and the contents returned by the

 

 

 

command do not contain parameters, the MS returns OK. If the

 

 

 

contents returned by the command contain parameters, the MS

 

 

 

returns the value range of each parameter, and then returns OK.

 

 

 

 

 

1.4.3 Abort Attributes of AT Commands

Abort means that the TE sends an instruction to abort a command when the command is being executed. An abort instruction must be sent before a command is completely executed. Therefore, the abort instruction is valid for a command whose execution consumes certain time; however, not all commands of this kind can be aborted. Whether a command can be aborted depends on the abort attribute of the command. Each AT command has its abort attribute, which is alternative. That is, the command is either abortive or not abortive. Abortive commands include certain basic commands and execution commands of action commands. Within 125 ms after the abortive commands are sent, no abort request is accepted. After 125 ms and before the commands are completely executed, if the module receives any character sent by the TE, the commands are aborted immediately.

Abortive commands are as follows:

zATD*99#

zATD*98#

zAT+CLCK

zAT+COPS commands (excluding AT+COPS=?)

zAT^MONI

zAT^MONP

zAT^SMONG

1.4.4Rules for Running AT Commands

1.Each command line contains only one AT command and ends with a carriage return character. In principle, users are not allowed to run S3/S4 format modification commands. This rule is applicable to the communication between the MT and TE programs.

2.To increase the readability and regularity of command and response formats, in addition to the original interfaces specified in standards and protocols, all new interfaces must observe the following rule: No space is added to the end of

Issue 02 (2010-11-23)

Huawei Proprietary and Confidential

6

Copyright © Huawei Technologies Co., Ltd.

 

 

Page 23
Image 23
Huawei MG323 manual Abort Attributes of AT Commands, Rules for Running AT Commands