6.3 Functions of PV1785B_1788

Start the software PV1785B_1788, the windows is as follows:

1

2

3

4

5

6

7

8

11

10

9

1

2

3

4

5

6

Configure the software operation environments.

Voltage chart, it can show you a chart of the voltage.

Current chart: it can show you a chart of the current.

To set the remote mode of power supply.

To set the output state ON/OFF.

To enable the local numeric key 7 , it means that if you select “Enable” on this button, when the

power supply is under remote control mode, you can press numeric key

7

to change the

control mode to front panel control mode.

 

 

7

8

9

Annunciators display.

Status bar, it can show you the power supply model, communication status and operation status.

To set current value, use the rotary knob to set the current value, the setup value and measurement value will be displayed.

10To make a program of voltage and current values for the power supply, or to set the output value quickly.

11Using the rotary knob to set the voltage value, the setup value and present value will be displayed in the 2 indicators.

30

Image 30
Contents Page Content General information About your safetyQuick Reference Protection from electric shockCertification and Warranty IntroductionCertification Front Panel at a Glance Function keys description Menu descriptionDisplay annunciators Rear Panel at a Glance CalPreliminary Checkout Connect the power cord and turn on the power supplyQuick Start Check the list of supplied itemsOutput Checkout Voltage Output CheckoutCurrent Output Checkout Verify that there is AC power to the power supply If the Power Supply Does Not Turn OnTo Adjust the Carrying Handle Verify the power-line voltage settingTo Rack Mount the Instrument Bench-top viewing positions Carrying positionSpecifications SpecificationsSupplemental Characteristics Maximum input powerUnit mm Environmental ConditionsFront-panel Operation Front-panel Operation OverviewConstant Voltage Operation Menu Operation Constant Current OperationSaving and Recalling Operation Set Maximum voltageMAX VoltInitiating the Output stateINIT OUT Setting the Key SoundKEY SoundSetting the Baud RateBAUDRATE Initiating the Output Voltage Init VoltSetting Address Address Setting password for function keysKEY LockRemote Operation Mode Communication settingIT-E131 Communication cable Communication protocol Setting the remote control mode 20HFrame format DescriptionSetting the output state ON/OFF 21H Setting the maximum output voltage 22HSetting the output voltage 23H Setting the output current 24H Setting the communication address 25HEntering the calibration mode 27H Reading the calibration state 28HCalibrating the voltage value 29H Calibrate the current value 2BHSetting calibration information 2EH Save the calibration data to Eeprom 2DHReading calibration information 2FH Restore the factory default calibration data 32H Enable the local key 37HReturn information of command operation in power supply 12H Calibration Current calibration ConfigurationVoltage calibration Finish calibratingReset to the default calibration settings InstallationPV1785B1788 Software Functions of PV1785B1788 1Configure the system Status barSetting Voltage and current Quickly settingProgram setting 4. GO/NG Test FunctionPresent Voltage/Current Chart Chart DescriptionSave and Open Page Limited One-Year Warranty Service Information USA