B&K 1787B, 1786B, 1788 To Rack Mount the Instrument, Bench-top viewing positions Carrying position

Page 11

Bench-top viewing positions

Carrying position

1.5 To Rack Mount the Instrument

You can mount the power supply in a standard 19-inch rack cabinet using the IT-E151 rack mount kit.

Note: Remove the carrying handle and the two plastic ears before rack-mounting the instrument.

To remove the handle, grasp the handle by sides and pull outwards and rotate it to a special position to let the arrow on the handle and the arrow on the plastic ears be in opposite directions, then pull the handle outward. After removing the handle, you can use a screwdriver to remove the two plastic ears.

To rack mount a single instrument, order rack mount kit IT-E151

Side view of rack mounting a single instrument

11

Image 11
Contents Page Content Protection from electric shock About your safetyQuick Reference General informationCertification Certification and WarrantyIntroduction Front Panel at a Glance Display annunciators Function keys descriptionMenu description Cal Rear Panel at a GlanceCheck the list of supplied items Connect the power cord and turn on the power supplyQuick Start Preliminary CheckoutCurrent Output Checkout Output CheckoutVoltage Output Checkout Verify the power-line voltage setting If the Power Supply Does Not Turn OnTo Adjust the Carrying Handle Verify that there is AC power to the power supplyBench-top viewing positions Carrying position To Rack Mount the InstrumentSpecifications SpecificationsMaximum input power Supplemental CharacteristicsEnvironmental Conditions Unit mmConstant Voltage Operation Front-panel OperationFront-panel Operation Overview Set Maximum voltageMAX Volt Constant Current OperationSaving and Recalling Operation Menu OperationInitiating the Output Voltage Init Volt Setting the Key SoundKEY SoundSetting the Baud RateBAUDRATE Initiating the Output stateINIT OUTSetting password for function keysKEY Lock Setting Address AddressIT-E131 Communication cable Remote Operation ModeCommunication setting Description Setting the remote control mode 20HFrame format Communication protocolSetting the output voltage 23H Setting the output state ON/OFF 21HSetting the maximum output voltage 22H Setting the communication address 25H Setting the output current 24HReading the calibration state 28H Entering the calibration mode 27HCalibrate the current value 2BH Calibrating the voltage value 29HReading calibration information 2FH Setting calibration information 2EHSave the calibration data to Eeprom 2DH Return information of command operation in power supply 12H Restore the factory default calibration data 32HEnable the local key 37H Calibration Finish calibrating ConfigurationVoltage calibration Current calibrationPV1785B1788 Software Reset to the default calibration settingsInstallation Functions of PV1785B1788 Status bar 1Configure the systemQuickly setting Setting Voltage and current4. GO/NG Test Function Program settingSave and Open Present Voltage/Current ChartChart Description Page Limited One-Year Warranty Service Information USA