6.3.5 Save and Open

To save the program settings, quickly settings, voltage sweep settings and GO/NG settings as PAR file.

To open the PAR file for reloading the program settings, quickly settings, voltage sweep settings and GO/NG settings.

6.3.6 Present Voltage/Current Chart

Double click the voltage chart, the voltage chart will be enlarged and will display as more details.

Double click the current chart, the current chart will be enlarged and will display with more details.

6.3.7. Chart Description

The voltage and current chart can help you to analyze voltage and current changes more easily. We take the voltage chart as the example to let you know how to use it. The chart window is as follows:

34

Image 34
Contents Page Content General information About your safetyQuick Reference Protection from electric shockIntroduction Certification and WarrantyCertification Front Panel at a Glance Menu description Function keys descriptionDisplay annunciators Rear Panel at a Glance CalPreliminary Checkout Connect the power cord and turn on the power supplyQuick Start Check the list of supplied itemsVoltage Output Checkout Output CheckoutCurrent Output Checkout Verify that there is AC power to the power supply If the Power Supply Does Not Turn OnTo Adjust the Carrying Handle Verify the power-line voltage settingTo Rack Mount the Instrument Bench-top viewing positions Carrying positionSpecifications SpecificationsSupplemental Characteristics Maximum input powerUnit mm Environmental ConditionsFront-panel Operation Overview Front-panel OperationConstant Voltage Operation Menu Operation Constant Current OperationSaving and Recalling Operation Set Maximum voltageMAX VoltInitiating the Output stateINIT OUT Setting the Key SoundKEY SoundSetting the Baud RateBAUDRATE Initiating the Output Voltage Init VoltSetting Address Address Setting password for function keysKEY LockCommunication setting Remote Operation ModeIT-E131 Communication cable Communication protocol Setting the remote control mode 20HFrame format DescriptionSetting the maximum output voltage 22H Setting the output state ON/OFF 21HSetting the output voltage 23H Setting the output current 24H Setting the communication address 25HEntering the calibration mode 27H Reading the calibration state 28HCalibrating the voltage value 29H Calibrate the current value 2BHSave the calibration data to Eeprom 2DH Setting calibration information 2EHReading calibration information 2FH Enable the local key 37H Restore the factory default calibration data 32HReturn information of command operation in power supply 12H Calibration Current calibration ConfigurationVoltage calibration Finish calibratingInstallation Reset to the default calibration settingsPV1785B1788 Software Functions of PV1785B1788 1Configure the system Status barSetting Voltage and current Quickly settingProgram setting 4. GO/NG Test FunctionChart Description Present Voltage/Current ChartSave and Open Page Limited One-Year Warranty Service Information USA