B&K 1787B, 1786B, 1788, 1785B instruction manual Rear Panel at a Glance, Cal

Page 7

ON

Output ON

Link The power supply is in communication

Oh

Overheat protection state

 

mode

CV The power supply is in constant

Rmt The power supply is in remote mode

 

voltage mode.

Cal

The power supply is in calibration mode

CC The power supply is in constant

 

The function keys are locked by password

 

current mode.

 

 

 

 

Unreg The output of the power supply

 

The rotate speed of cooling fan

 

is unregulated (neither CV nor CC)

 

 

 

 

 

 

 

 

The Rear Panel at a Glance

1

2

3

4

5

?Cooling window

?DB9 interface connector

?110V/220V selector

?Fuse

?Power socket

7

Image 7
Contents Page Content Protection from electric shock About your safetyQuick Reference General informationIntroduction Certification and WarrantyCertification Front Panel at a Glance Menu description Function keys descriptionDisplay annunciators Cal Rear Panel at a GlanceCheck the list of supplied items Connect the power cord and turn on the power supplyQuick Start Preliminary CheckoutVoltage Output Checkout Output CheckoutCurrent Output Checkout Verify the power-line voltage setting If the Power Supply Does Not Turn OnTo Adjust the Carrying Handle Verify that there is AC power to the power supplyBench-top viewing positions Carrying position To Rack Mount the InstrumentSpecifications SpecificationsMaximum input power Supplemental CharacteristicsEnvironmental Conditions Unit mmFront-panel Operation Overview Front-panel OperationConstant Voltage Operation Set Maximum voltageMAX Volt Constant Current OperationSaving and Recalling Operation Menu OperationInitiating the Output Voltage Init Volt Setting the Key SoundKEY SoundSetting the Baud RateBAUDRATE Initiating the Output stateINIT OUTSetting password for function keysKEY Lock Setting Address AddressCommunication setting Remote Operation ModeIT-E131 Communication cable Description Setting the remote control mode 20HFrame format Communication protocolSetting the maximum output voltage 22H Setting the output state ON/OFF 21HSetting the output voltage 23H Setting the communication address 25H Setting the output current 24HReading the calibration state 28H Entering the calibration mode 27HCalibrate the current value 2BH Calibrating the voltage value 29HSave the calibration data to Eeprom 2DH Setting calibration information 2EHReading calibration information 2FH Enable the local key 37H Restore the factory default calibration data 32HReturn information of command operation in power supply 12H Calibration Finish calibrating ConfigurationVoltage calibration Current calibrationInstallation Reset to the default calibration settingsPV1785B1788 Software Functions of PV1785B1788 Status bar 1Configure the systemQuickly setting Setting Voltage and current4. GO/NG Test Function Program settingChart Description Present Voltage/Current ChartSave and Open Page Limited One-Year Warranty Service Information USA