B&K 1785B, 1786B, 1788, 1787B instruction manual Content

Page 2

Content

 

Quick Reference

3

About your safety

3

 

General information

3

 

Protection from electric shock

3

 

Definition of users

3

Introduction

4

The Front Panel at a Glance

5

Function keys description

6

Menu description

6

Display annunciators

6

The Rear Panel at a Glance

7

Chapter 1 Quick Start

8

1.1

Preliminary Checkout

8

1.2

Output Checkout

9

 

1.2.1 Voltage Output Checkout

9

 

1.2.2 Current Output Checkout

9

1.3

If the Power Supply Does Not Turn On

10

1.4

To Adjust the Carrying Handle

10

1.5

To Rack Mount the Instrument

11

Chapter 2 Specifications

12

2.1

Specifications

12

2.2

Supplemental Characteristics

13

Chapter 3 Front-panel Operation

15

3.1

Front-panel Operation Overview

15

3.2

Constant Voltage Operation

15

3.3

Constant Current Operation

16

3.4

Saving and Recalling Operation

16

3.5

Menu Operation

16

Chapter 4 Remote Operation Mode

19

4.1

Communication setting

19

4.2

DB9 interface details

19

4.3

Frame format

20

4.4

Communication protocol

20

Chapter 5 Calibration

27

 

5.1 Configuration

28

5.2

Voltage calibration

28

5.3

Current calibration

28

5.4

Reset to the default calibration settings

29

Chapter 6 PV1785B_1788 Software

29

6.1

Introduction

29

6.2

System installation

29

6.3

PV1785B_1788 Functions

30

 

6.3.1Configure the system

31

 

6.3.2 Status bar

31

 

6.3.3 Setting Voltage and current

32

 

6.3.4. GO/NG Test Function

33

 

6.3.5 Save and Open

34

 

6.3.6 Present Voltage/Current Chart

34

 

6.3.7. Chart Description

34

Certification and Warranty

4

 

Certification

 

Warranty

 

Limitation of Warranty

2

Image 2
Contents Page Content General information About your safetyQuick Reference Protection from electric shockCertification Certification and WarrantyIntroduction Front Panel at a Glance Display annunciators Function keys descriptionMenu description Rear Panel at a Glance CalPreliminary Checkout Connect the power cord and turn on the power supplyQuick Start Check the list of supplied itemsCurrent Output Checkout Output CheckoutVoltage Output Checkout Verify that there is AC power to the power supply If the Power Supply Does Not Turn OnTo Adjust the Carrying Handle Verify the power-line voltage settingTo Rack Mount the Instrument Bench-top viewing positions Carrying positionSpecifications SpecificationsSupplemental Characteristics Maximum input powerUnit mm Environmental ConditionsConstant Voltage Operation Front-panel OperationFront-panel Operation Overview Menu Operation Constant Current OperationSaving and Recalling Operation Set Maximum voltageMAX VoltInitiating the Output stateINIT OUT Setting the Key SoundKEY SoundSetting the Baud RateBAUDRATE Initiating the Output Voltage Init VoltSetting Address Address Setting password for function keysKEY LockIT-E131 Communication cable Remote Operation ModeCommunication setting Communication protocol Setting the remote control mode 20HFrame format DescriptionSetting the output voltage 23H Setting the output state ON/OFF 21HSetting the maximum output voltage 22H Setting the output current 24H Setting the communication address 25HEntering the calibration mode 27H Reading the calibration state 28HCalibrating the voltage value 29H Calibrate the current value 2BHReading calibration information 2FH Setting calibration information 2EHSave the calibration data to Eeprom 2DH Return information of command operation in power supply 12H Restore the factory default calibration data 32HEnable the local key 37H Calibration Current calibration ConfigurationVoltage calibration Finish calibratingPV1785B1788 Software Reset to the default calibration settingsInstallation Functions of PV1785B1788 1Configure the system Status barSetting Voltage and current Quickly settingProgram setting 4. GO/NG Test FunctionSave and Open Present Voltage/Current ChartChart Description Page Limited One-Year Warranty Service Information USA