3. Program setting

Program: Right-click on the Program area, the program tools (Append a line, Insert a line, Delete a line, Delete Select etc.) will appear on the window. Click the tools to program the steps.

Double-click on each value to change them from key board as you desired. Also you can change the time unit (hour/minute/second) by clicking on “Sec”.

After programming, you can select a run mode for your program. (Run mode includes Once, Repeat and Custom).

Click “Run” button to send the program settings to the power supply. The power supply’s output will respond to the program.

Click “Stop” button to stop sending the program settings to the power supply. The power supply state will return to the state before the program running.

Click “Chart” to show the voltage and current chart of the program.

You can do some analysis on the chart or print the chart. The chart is as follows:

6.3.4. GO/NG Test Function

GO/NG is an auto test function, to test if the EUT (equipment under test) can meet the specification. To use this function, follow up the steps below:

1.Right-click on the window, the edit tools (Append a line, Insert a line, Delete a line, Delete Select etc.) will appear on the window. Use the edit tools to edit the test steps.

2.To set the Voltage, Max Amps, Min Amps and Delay time according to the specifications of the EUT.

3.Click the Run button to start the test. If the Real Amps of all steps are in the range of Min Amps to Max Amps, then the EUT will pass the test, the Pass window will appear.

4.If there is a Real Amps beyond the range in any step, the EUT will not pass the test.

33

Image 33
Contents Page Content Quick Reference About your safetyGeneral information Protection from electric shockCertification and Warranty IntroductionCertification Front Panel at a Glance Function keys description Menu descriptionDisplay annunciators Cal Rear Panel at a GlanceQuick Start Connect the power cord and turn on the power supplyPreliminary Checkout Check the list of supplied itemsOutput Checkout Voltage Output CheckoutCurrent Output Checkout To Adjust the Carrying Handle If the Power Supply Does Not Turn OnVerify that there is AC power to the power supply Verify the power-line voltage settingBench-top viewing positions Carrying position To Rack Mount the InstrumentSpecifications SpecificationsMaximum input power Supplemental CharacteristicsEnvironmental Conditions Unit mmFront-panel Operation Front-panel Operation OverviewConstant Voltage Operation Saving and Recalling Operation Constant Current OperationMenu Operation Set Maximum voltageMAX VoltSetting the Baud RateBAUDRATE Setting the Key SoundKEY SoundInitiating the Output stateINIT OUT Initiating the Output Voltage Init VoltSetting password for function keysKEY Lock Setting Address AddressRemote Operation Mode Communication settingIT-E131 Communication cable Frame format Setting the remote control mode 20HCommunication protocol DescriptionSetting the output state ON/OFF 21H Setting the maximum output voltage 22HSetting the output voltage 23H Setting the communication address 25H Setting the output current 24HReading the calibration state 28H Entering the calibration mode 27HCalibrate the current value 2BH Calibrating the voltage value 29HSetting calibration information 2EH Save the calibration data to Eeprom 2DHReading calibration information 2FH Restore the factory default calibration data 32H Enable the local key 37HReturn information of command operation in power supply 12H Calibration Voltage calibration ConfigurationCurrent calibration Finish calibratingReset to the default calibration settings InstallationPV1785B1788 Software Functions of PV1785B1788 Status bar 1Configure the systemQuickly setting Setting Voltage and current4. GO/NG Test Function Program settingPresent Voltage/Current Chart Chart DescriptionSave and Open Page Limited One-Year Warranty Service Information USA