1.17 Message Features
2) SLT setting
Extension Jack No. | SMS Centre Number for | SMS Centre Number for | SMS Sub- |
| Sending | Receiving | address |
|
|
|
|
Jack 01 | 89*1 P*21112223333 | 1112224444 | 1 |
Jack 02 | 89*1 P*21112223333 | 1112224444 | 2 |
Jack 07 | 89*1 P*21112223333 | 1112224444 | 1 |
(Cont.) : | : | : | : |
: | : | : | : |
|
|
|
|
*1 89: Outside (CO) Line Access number used to make SMS centre calls using the fixed outside (CO) lines.
When the SMS centre can receive an SMS message from any telephone number, the Automatic Line Access number or Outside (CO) Line Access number can also be used respectively.
*2 P: Pause
In this example:
a)To send an SMS message to the SLT connected to extension jack 01, enter "38470011" as the destination.
b)To send an SMS message to the SLT connected to extension jack 02, enter "38470012" as the destination.
c)To send an SMS message to the SLT connected to extension jack 07, enter "38470021" as the destination.
[Programming Example: SMS Routing Table without
When the SMS centre number used to receive SMS centre calls is "1112224444" and the telephone numbers of each outside (CO) line are "3847001" for CO 1, "3847002" for CO 2, and "3847003" for CO 3, programme as follows:
1)PBX setting
SMS Centre Number for Receiving: 1112224444
Location No. | Outside (CO) Line No. | Extension Jack No. |
|
|
|
1 | CO 1 | Jack 01 |
|
|
|
2 | CO 2 | Jack 02 |
|
|
|
3 | CO 3 | Jack 03 |
|
|
|
If the SMS centre does not support
One location can be used for each outside (CO) line telephone number.
Feature Guide
131