3.3 PT Programming
Fixed Button
Function
FLASH
CLEAR
Entering System Programming Mode
Using a PT to perform system programming allows an authorised administrator to set a wide range of PBX features and parameters. To enter system programming mode, the system password is required. With the system password, all system programming is accessible.
#
Note
System Password for
1234
Programming No.
3 digits
means default value throughout these programming instructions.
Entering Manager Programming Mode
Using a PT to perform manager programming allows the manager extension (extension jack 01) to set certain PBX features and parameters. To enter manager programming mode, the extension password for the manager (manager password) is required.
With the manager password, the following 4 system programming settings are accessible:
•System Speed Dialling Number [001]
•System Speed Dialling Name [011]
•DISA Security Code [512]
•DISA Security Code Digits [530]
#
Notes
Extension Password for Manager
Programming No.
3 digits
•The system password may be entered instead of the manager password.
•With the manager password, the manager can also set a password to each extension, and print out call log information for each extension. For more information on how to assign a password to each extension including the manager password and to print out call log information for each extension, refer to the User Manual ( 2.1.7 Changing System Settings Using Programming Mode, 3.2.2 Printing and Clearing Call Logs).
Feature Guide
193