Panasonic kx-tea308 manual 2.3.2PT Programming, Description, Conditions, Programming Type, Example

Models: kx-tea308

1 278
Download 278 pages 30.5 Kb
Page 175
Image 175
2.3.2PT Programming

2.3 System Data Control

2.3.2PT Programming

Description

A proprietary telephone (PT) can be used to customise the settings of the PBX or of an extension, using the following programming features:

Programming Type

Description

Example

Authorised

 

Programmer

 

 

 

 

 

 

 

Personal

Used by an extension user to

One-touch Dialling,

Extension user

Programming

customise the extension's

Line Preference—

 

 

settings.

Outgoing, etc.

 

 

 

 

 

System Programming

Used by an authorised party to

System Password,

Authorised

 

customise the PBX.

Extension Number, etc.

administrator

 

 

 

 

Manager

Used by the manager to

System Speed Dialling

Manager

Programming

customise 4 system

Number, Extension

 

 

programming settings of the

Password Set, Call Log

 

 

PBX, set a password to each

Printout for Each

 

 

extension, and print out call log

Extension, etc.

 

 

information for each extension.

 

 

 

 

 

 

Conditions

The manager extension is the extension that is connected to the lowest-numbered jack (jack 01) of the PBX and can therefore perform manager programming.

Only one system programming (including PC programming) or manager programming session is permitted at a time. These 2 programming features cannot be performed simultaneously by 2 users.

During programming, the PT is considered to be busy and will not receive calls.

System Password

To access system programming, the administrator system password must be entered. The system password is set at the factory but can be changed through system programming (Programming Type System Password [002]). The administrator can programme all system programming.

Manager Password

To set the manager password, it is necessary to use the system password to perform Extension Password Set. Once set, the manager password can be used to access manager programming. The manager can assign a password to each extension (extension password).

Personal Programming Data Reset

A PT user can simultaneously reset all settings made through personal programming (Line Preference—Incoming/Outgoing, Call Waiting Tone Type Selection, etc.) to their default settings. This feature also cancels pressing the AUTO ANS/MUTE button in the Hands-free Answerback feature and the Room Monitor feature.

System Programming Data Reset

The PBX can return all or specific settings made through system programming to their default settings based on the following parameters (Authorised System Data Clear [999]):

a)All para: All data

b)System para: All data except for "CO para", "Extn. para", and "DSS para"

c)CO para: The data assigned for each outside (CO) line

d)Extn. para: The data assigned for each extension

Feature Guide 175

Page 175
Image 175
Panasonic kx-tea308 manual 2.3.2PT Programming, Description, Conditions, Programming Type, Example, Authorised, Programmer