B&K 1786B, 1788, 1785B, 1787B instruction manual Setting Voltage and current, Quickly setting

Page 32

6.3.3 Setting Voltage and current

1. Setting voltage/current by rotary knob

Use mouse to click on the rotary knob and move mouse to change the value. You also can use mouse wheel, or Page Up/Down keys and arrow keys (?, ?, ? , ? ) from the keyboard to change the voltage value more slightly. The setup value will be displayed on the second line indicator.

Use mouse to click on the rotary knob and move mouse to change the value. Also you can use mouse wheel, Page Up/Down keys and arrow keys (?, ?, ? , ? ) from the keyboard to change the current value more slightly. The setup value will be displayed on the second line indicator.

Note: Before you set the current and voltage value from the computer, please change the

operation mode to PC Control mode by pressing button.

2. Quickly setting

Hot Key: Right-click each Hotkey Button, it will display as “Modify Voltage/Current”. Click “Modify/Voltage/ Current”, it will display as follows, change the voltage/current value as you desired, then click OK button to confirm.

Voltage Sweep: To set voltage sweep. For example, StartValue=0.0V, Stop Value=10V, Voltage Step=2V, TimeDelay=2s. When you click the Run button, the voltage will change according to the voltage sweep setup value, then you can click Stop button to stop the voltage sweep. You can also click the Chart button, the voltage chart will display as follows:

32

Image 32
Contents Page Content About your safety Quick ReferenceGeneral information Protection from electric shockCertification Certification and WarrantyIntroduction Front Panel at a Glance Display annunciators Function keys descriptionMenu description Rear Panel at a Glance CalConnect the power cord and turn on the power supply Quick StartPreliminary Checkout Check the list of supplied itemsCurrent Output Checkout Output CheckoutVoltage Output Checkout If the Power Supply Does Not Turn On To Adjust the Carrying HandleVerify that there is AC power to the power supply Verify the power-line voltage settingTo Rack Mount the Instrument Bench-top viewing positions Carrying positionSpecifications SpecificationsSupplemental Characteristics Maximum input powerUnit mm Environmental ConditionsConstant Voltage Operation Front-panel OperationFront-panel Operation Overview Constant Current Operation Saving and Recalling OperationMenu Operation Set Maximum voltageMAX VoltSetting the Key SoundKEY Sound Setting the Baud RateBAUDRATEInitiating the Output stateINIT OUT Initiating the Output Voltage Init VoltSetting Address Address Setting password for function keysKEY LockIT-E131 Communication cable Remote Operation ModeCommunication setting Setting the remote control mode 20H Frame formatCommunication protocol DescriptionSetting the output voltage 23H Setting the output state ON/OFF 21HSetting the maximum output voltage 22H Setting the output current 24H Setting the communication address 25HEntering the calibration mode 27H Reading the calibration state 28HCalibrating the voltage value 29H Calibrate the current value 2BHReading calibration information 2FH Setting calibration information 2EHSave the calibration data to Eeprom 2DH Return information of command operation in power supply 12H Restore the factory default calibration data 32HEnable the local key 37H Calibration Configuration Voltage calibrationCurrent calibration Finish calibratingPV1785B1788 Software Reset to the default calibration settingsInstallation Functions of PV1785B1788 1Configure the system Status barSetting Voltage and current Quickly settingProgram setting 4. GO/NG Test FunctionSave and Open Present Voltage/Current ChartChart Description Page Limited One-Year Warranty Service Information USA