American Power Conversion MX28B2400, MX28B4800 manual 2 MX28B Block Diagram

Page 9

Figure 2.2-2 MX28B Block Diagram

MX28B1200/2400 MX28B1200/4800 –48 VDC User’s Manual

Page 4

Image 9
Contents VDC Power Systems Table of Contents Commissioning and Preventive Maintenance APC Worldwide Customer Support Limited Product Warranty Revision Date Description Revision HistoryGeneral Precautions Safety FirstHow to Use This Manual IntroductionGeneral Information 1 MX28B-1200 -48 VDC Power Plant Rectifier Bay 2 MX28B Block Diagram Mechanical Installation InstallationUnpacking Equipment Room / LocationMounting Power Bus Connections2 MX28B-1200-2400 has a maximum 5 Circuit Breaker / LVD Expansion Board Circuit Breaker/LVD Ribbon Cable ConnectionsAC Power Connections Fuse Alarm Ribbon Cable ConnectionsVentilation 1 AC Input Wiring Planning the Battery Installation Battery Connections1 Battery Cable Connection Locations Connecting the Battery CablesDC System Grounding 2 Battery Probe ConnectionDC Plug-in Circuit Breakers DC Power Output Over-Current ProtectionBreaker Part Number Rating 2 Plug-in Circuit Breakers 4 Bolt-in Circuit Breakers DC Bolt-in Circuit Breakers5 Telecom Fuses Telecom FusesPlug-in Circuit Breaker Installation Installation of Circuit Breakers and Fuses2 Circuit Breaker Alarm Wiring Bolt-in Circuit Breaker InstallationGMT Fuse Installation Telecom Fuse InstallationCable Size Considerations Load ConnectionsCircuit Breaker Connections 1 to 50 Amps Circuit Breaker Connections 60-100 AmpsGMT Fuse Connections Monitoring and Relay Output ConnectionsFront Panel DB9 Connection Smart Cable DB9 ConnectionRelay Output Connections RJ45 Ethernet ConnectorNO-NC-C External Alarm Input ConnectionsRectifier Module Installation Electrical Installation Commissioning and Preventive MaintenanceBattery Visual and Safety Inspection Pre-Commissioning InspectionAC Power Up CommissioningInitial Set-up Battery Power Up DC Power UpRectifier Test LVD TestCircuit Breaker/ Fuse Test Battery Temperature CompensationUser Inputs Output RelaysFinal Inspection Operation Technical DescriptionRectifier Management System Output Capacity System ManagementSystem Voltage Control System CurrentSystem Status and Alarm Reporting Battery ManagementBattery Charging and Protection DC DistributionControls and Indicators Battery/Load Low Voltage DisconnectFront Panel User Interface Parameter Locations, Descriptions, and Default Values Status Alarms System Modules Batt PIN OEMNo Alarms Alarm ItemAddress SwitzerBatt HT Thr Batt HT Alm70.0 C Batt HV AlmMajor Cir Bkr 1 Alm m+Cir Bkr 72 Almm+ Comp HkneeFuse 16 Alm Fuse 1 AlmHw Batt C Almm+ MinorLVD Option LVD Reset48.00 LVD TripSec Out-Rly 1 Dly m+Out-Rly 6 Dly m+ Relay MajorRect 1 Desc DisableMRF28H54 Rect 1ofN Almm+Sys HV Thr Sys HV AlmSys LT Alm Sys LT Thr90025 TimeControl Unit Menu Structure SYS MS System Module SET-ALM Setup DAV e l C o n d L e v e l I r d L e v e l U r t h L e v e l SYS Sysin Modrec AM Info Modfuse LM Alias Fuse MOD Modlvd Modlvd LM Param Alarm Outputs Output Relays Front Panel LED IndicatorsSection External Alarm Inputs Input Relays Remote Monitoring Command and Monitoring ProtocolDescription Physical ConnectionsSystem Visual and Safety Inspection Preventive MaintenanceEquipment InspectionTest System Voltage TestRectifier Current Test System Temperature Test Rectifier Alarm TestBattery Current Test Rectifier Current Share TestBattery Preventive Maintenance Procedure Battery Temperature TestFinal Inspection AC Input Specifications1MRF28H54BV Rectifiers 1MRF28H54BV50 RectifiersRectifiers VDCPower Shelf Control Unit Mechanical EnvironmentalCompliance US and Canada APC Worldwide Customer SupportToll Free WorldwideLimited Product Warranty