American Power Conversion S15BLK owner manual Technical Specifications, Input, Output

Page 44

Technical Specifications

The table on the following pages contains the technical specifications for the Model S15 and S10 S Type Power Conditioner with Battery Backup.

FCC Compliance Information

This device complies with Part 68 and Part 15 of the Federal Communications Commission (FCC) rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

As required, the bottom of this equipment contains the Registration Number and Ringer Equivelance Number (REN) for this euipment, as well as other information. If requested, this information must be provided to the telephone company.

S10 &

S10BLK

S15 &

S15BLK

External

Battery

Pack (SBATT &

SBATTBLK)

Input:

Voltage Range for

90V to 144V

90V to 144V

N/A

Operating on Utility

 

 

 

 

 

 

 

Nominal Voltage

120 Vac

120 Vac

48 Vdc

 

 

 

 

Allowable Frequency for

47 to 63 Hz

47 to 63 Hz

N/A

Operating on Utility

 

 

 

 

 

 

 

Rated Input Current

9 Amps

12 Amps

N/A

 

 

 

 

Circuit Breaker Rating

15 Amps

15 Amps

N/A

 

 

 

 

Output:

 

 

 

Number of Outlets

12 (all outlets surge

12 (all outlets

N/A

 

protected,

surge protected,

 

 

conditioned,

conditioned,

 

 

regulated with

regulated with

 

 

battery backup)

battery backup)

 

 

 

 

 

Outlet Type

NEMA 5-15R

NEMA 5-15R

N/A

 

 

 

 

Rated VA Capacity

1000 VA

1440 VA

N/A

 

 

 

 

Rated Watt Capacity,

700 Watts

1000 Watts

N/A

continuous

 

 

 

 

 

 

 

Rated Output Current

9 Amps

12 Amps

N/A

 

 

 

 

2-24

Image 44
Contents Model S15 Shown Page Safety Information Example of Antenna Grounding PER National Electric Code NEC Safety Symbols Protect Your InvestmentRegistration VerificationPage Table of Contents Page Introduction Package Contents Features Safety PrecautionsUnit Power Capacity Surge Protection Removable Support Feet Front Panel Controls and IndicatorsFront and Rear Panels Up Arrow Push Button Status Push ButtonVacuum Fluorescent Display LOW Battery Status Indicator Line OK Status IndicatorFiltering Status Indicator Overload Status IndicatorRear Panel Connectors and Circuit Breaker Setup Push ButtonRegulating Status Indicator Delayed 2 Status IndicatorP q r s Surge Protected COAX/RF Connectors Additional Surge Protected COAX/RF ConnectorsInput Power Connector Ethernet Surge Protected JacksSurge Protected Telephone Jacks TEL/DVR/SAT/DSL Cooling FanInstallation Removing the Battery PackInstalling the Unit Inserting and Connecting the Battery Front Bezel RemovalInstall the battery retaining bar Powering On and Connecting Equipment Performing the System TestOUTLET2 on Selftest is on ON-LINE Selftest Screen No External Battery Connected Screen Status and Informational Screens Status ScreensSystem Load Xxxw Load XXX% Informational Screens Source Xxxxxxx EST. Runtime Xhrs ScreenFirmware Version Xxxxxxx Screen Firmware Version Xxxxxxx ScreenModel Number and Serial Number Screen Phone Number and Technical Support Internet AddressConnecting the Components Input FREQUENCY/OUTPUT Frequency ScreenS10/S15 Set Up Using Front-Panel Controls Audible Alarm Setting Screen Sensitivity High Setting Screen GO to Battery if Xxxv Setting Screen Lowbattwarning Setting Screen Do Quik Selftest Screen DISPLY-BEEP Test Screen Initialization Complete Limited Warranty Output Technical SpecificationsInput Surge Protection PhysicalPage Troubleshooting Unit will not turn onCircuit breaker has tripped Technical Support Replace Battery LED is illuminatedContact Information Page Page APC Worldwide Customer Support 990-1906D 2007