10Surge Protected Telephone Jacks (TEL/DVR/SAT/DSL)

The S15 has a telephone line splitter (2-line 4-wire with splitter) with surge protection for components connected via telephone line. Connect the supplied RJ11 telephone cable from the wall jack (source) to the telephone line connector marked IN. Connect the other telephone cables to the connectors marked OUT A and/or OUT B to the equipment to be protected (telephone, DVR, DSS, or DSL). The S10 has 1-line 2-wire (no splitter) connector.

Note: The splitter only splits two lines (two lines running through one phone cable). It cannot be used to physically separate a single line into two lines, such as with a Y connection.

11DATA PORT Jack (USB)

Enables the S10 and S15 to communicate with the included PowerChute Personal Edition software. If the unit is also protecting a home computer, the software will automatically save files and gracefully shutdown the operating system if the S10 or S15 are about to shutdown due to a low battery condition. For more information regarding the installation and use of this software, see the documentation contained on the PowerChute Personal Edition CD.

12Cooling Fan

Both units provide a microprocessor controlled, ultra-quiet cooling fan, which keeps the unit cool when operating on battery power.

1-12

Image 20
Contents Model S15 Shown Page Safety Information Example of Antenna Grounding PER National Electric Code NEC Safety Symbols Protect Your InvestmentRegistration VerificationPage Table of Contents Page Introduction Package Contents Features Safety PrecautionsUnit Power Capacity Surge Protection Removable Support Feet Front Panel Controls and IndicatorsFront and Rear Panels Up Arrow Push Button Status Push ButtonVacuum Fluorescent Display LOW Battery Status Indicator Line OK Status IndicatorFiltering Status Indicator Overload Status IndicatorRear Panel Connectors and Circuit Breaker Setup Push ButtonRegulating Status Indicator Delayed 2 Status IndicatorP q r s Surge Protected COAX/RF Connectors Additional Surge Protected COAX/RF ConnectorsInput Power Connector Ethernet Surge Protected JacksSurge Protected Telephone Jacks TEL/DVR/SAT/DSL Cooling FanInstallation Removing the Battery PackInstalling the Unit Inserting and Connecting the Battery Front Bezel RemovalInstall the battery retaining bar Powering On and Connecting Equipment Performing the System TestOUTLET2 on Selftest is on ON-LINE Selftest Screen No External Battery Connected Screen Status and Informational Screens Status ScreensSystem Load Xxxw Load XXX% Informational Screens Source Xxxxxxx EST. Runtime Xhrs ScreenFirmware Version Xxxxxxx Screen Firmware Version Xxxxxxx ScreenModel Number and Serial Number Screen Phone Number and Technical Support Internet AddressConnecting the Components Input FREQUENCY/OUTPUT Frequency ScreenS10/S15 Set Up Using Front-Panel Controls Audible Alarm Setting Screen Sensitivity High Setting Screen GO to Battery if Xxxv Setting Screen Lowbattwarning Setting Screen Do Quik Selftest Screen DISPLY-BEEP Test Screen Initialization Complete Limited Warranty Output Technical SpecificationsInput Surge Protection PhysicalPage Troubleshooting Unit will not turn onCircuit breaker has tripped Technical Support Replace Battery LED is illuminatedContact Information Page Page APC Worldwide Customer Support 990-1906D 2007