American Power Conversion S15BLK owner manual Status Push Button, Vacuum Fluorescent Display

Page 14

1DELAYED 1 Status Indicator

2

3

4

5

When lit (blue), conditioned power is being supplied to equipment connected to the rear-panel outlets marked Delayed 1.

ON BATTERY Status Indicator

When lit (orange), the Power Conditioner is operating on power from the internal Battery Pack and is providing clean power to the connected equipment. The unit will go On Battery when the input utility voltage either drops below the user-selectable level, goes above the user-selectable level, or is experiences an outage, or momentary input utility voltage drops or surges.

STATUS Push Button

When you press this pushbutton, it provides the unit status for: Input and Output Voltage, Input and Output Frequency, Telephone and Internet contact information, Model and Serial Number, Firmware (FW) Version number, Source (Standby, Battery, or Utility), Estimated Runtime (in hours or minutes), and Estimated Runtime (in hours) with a Fuel indication (as a percentage with bar graph) indication, as well as System Load (in watts), and Load (as a percentage in bar graph form).

This push button can also be used to set a default screen, which is a screen that is automatically displayed all the time.

Vacuum Fluorescent Display*

The vacuum flourescent display (VFD) conveys information about unit and power status. It is also used to display information when changing unit settings.

Note: The VFD and light emitting diodes (LEDs) can be dimmed or turned off independently of each other via the front control panel SETUP push button.

Up Arrow Push Button

This button is used to increase or turn on parameters for various user-selectable settings such as: Audible Alarms, Sensitivity, Display Dimmer, LED Dimmer, Go To Bat If, Outlet 1 & 2 Delay (in seconds), Low Bat Warning, and so on.

1-6

Image 14
Contents Model S15 Shown Page Safety Information Example of Antenna Grounding PER National Electric Code NEC Registration Safety SymbolsProtect Your Investment VerificationPage Table of Contents Page Introduction Package Contents Features Safety PrecautionsUnit Power Capacity Surge Protection Removable Support Feet Front Panel Controls and IndicatorsFront and Rear Panels Up Arrow Push Button Status Push ButtonVacuum Fluorescent Display Filtering Status Indicator LOW Battery Status IndicatorLine OK Status Indicator Overload Status IndicatorRegulating Status Indicator Rear Panel Connectors and Circuit BreakerSetup Push Button Delayed 2 Status IndicatorP q r s Surge Protected COAX/RF Connectors Additional Surge Protected COAX/RF ConnectorsInput Power Connector Ethernet Surge Protected JacksSurge Protected Telephone Jacks TEL/DVR/SAT/DSL Cooling FanInstallation Removing the Battery PackInstalling the Unit Inserting and Connecting the Battery Front Bezel RemovalInstall the battery retaining bar Powering On and Connecting Equipment Performing the System TestOUTLET2 on Selftest is on ON-LINE Selftest Screen No External Battery Connected Screen Status and Informational Screens Status ScreensSystem Load Xxxw Load XXX% Informational Screens Source Xxxxxxx EST. Runtime Xhrs ScreenFirmware Version Xxxxxxx Screen Firmware Version Xxxxxxx ScreenModel Number and Serial Number Screen Phone Number and Technical Support Internet AddressConnecting the Components Input FREQUENCY/OUTPUT Frequency ScreenS10/S15 Set Up Using Front-Panel Controls Audible Alarm Setting Screen Sensitivity High Setting Screen GO to Battery if Xxxv Setting Screen Lowbattwarning Setting Screen Do Quik Selftest Screen DISPLY-BEEP Test Screen Initialization Complete Limited Warranty Output Technical SpecificationsInput Surge Protection PhysicalPage Troubleshooting Unit will not turn onCircuit breaker has tripped Technical Support Replace Battery LED is illuminatedContact Information Page Page APC Worldwide Customer Support 990-1906D 2007