A

System Option 002

General Information

This option facilitates the operation of the power supply in an automated system. Four major circuit blocks provide:

1 ) remote analog programming of the supply's output by three different control methods; 2) signals indicating the power supply modes and conditions; 3) two different digital methods of remote control; and 4) the outputs of three bias supplies for use with external circuitry.

The power supply equipped with this option can be operated from either a 6940B Multiprogrammer equipped with a 69520A power supply programming card or a 6942A Multiprogrammer equipped with a 69709A power supply programming card.

Remote Programming. Through this interface both the output voltage and current can be remote programmed by either an external voltage source, resistance, or a current sink.

Status Indicators. Six optically isolated lines provide open-collector digital outputs which indicate the following states: constant voltage mode, constant current mode, output unregulated, ac dropout, overvoltage, and overtemperature.

Remote Control. Two optically isolated methods of remote control are available. 0ne method requires a negative going edge, which sets a latch on the 002 card to inhibit the power supply. The latch and OVP are reset by a negative-going pulse on another input line. The second method of remote control requires a low logic level to inhibit the power supply for the duration of the low level.

Bias Supplies. The outputs of three bias supplies are also available at the option connector. These outputs are + 15V, -15V, and +5V.

Monitoring. The 002 Option Board provides two monitoring outputs (I.MON. and V.MON) available at the option connector. They both vary from 0 to 5V corresponding to a 0 to full scale output.

Other modes of operation, such as multiple supply system control, are described in detail in later paragraphs. Modes such as Auto Series, Auto Parallel, and Auto Tracking Operation are described in the Operating Manual.

Specifications

Table A-1 provides specifications for the Option 002. This table is referred to periodically throughout the text of this Appendix.

Option 002 Hardware

The Option 002 hardware consists of a single printed circuit board installed at the right side (facing the front-panel) of the chassis. Two cables connect the option board to the A2 control board at A2J1 and A2J2. Connections between the option board and external circuits are made via the 37-pin connector mounted on the option board and available at the rear of the power supply. A mating connector is also included for the user's convenience.

79

Image 79
Contents Autoranging Certification Safety Summary Printing History Safety Symbol DefinitionsTable of Contents Replaceable Parts Scope TroubleshootingCircuit Diagrams Safety ConsiderationsItem Description Manual RevisionsOperation Verification Tests Calibration ProcedureIntroduction Test Equipment RequiredTest Equipment Required Type Required Characteristics USE Recommended Model1KVA Initial SetupMON Calibration ProcedureIout VoutMeasurement Techniques Performance TestsCR7 Constant Voltage CV Tests Current-Monitoring Resistor SetupBasic Test Setup RMS Measurement Test Setup, CV Pard Test Peak-To-Peak Measurement Test Setup, CV Pard Test KHz Noise, CV Peak-to-Peak Pard 6023A 6028ALoad Transient Recovery Waveform Constant Current CC Tests CC Pard Test Setup Initial Troubleshooting Procedures TroubleshootingWAVEFORM/CONDITIONS Source Control Board Test Connector, A2J7PIN no Signal Name VdcElectrostatic Protection Repair and ReplacementA2 Control Board Removal A1 Main Board Removal A4 Power Mesh Board RemovalOverall Troubleshooting Procedure A3 Front-Panel Board RemovalMeasurement Using the TablesSetup NodeMain Troubleshooting Setup Main Troubleshooting SetupModified Mains Cord Set For Troubleshooting Front-Panel Troubleshooting Troubleshooting No-Output FailuresA2J7-26 A2J7-25 PWM-ON PWM-OFF Defective Check Functional CircuitsBoard Node + Measurement Source Troubleshooting Bias SuppliesSymptoms Defective Circuit Check Components Symptoms Defective Check Functional Circuits BoardMeasurement Source Node +Node + N0DE Setup Measurement Power Section BlocksTroubleshooting AC-Turn-on Circuits Setup Measurement SourceRelay Enable Troubleshooting PWM & ClockPower Limit PWM-OFF Troubleshooting DC-To-DC Converter+ OUT PWM-ONTroubleshooting CC Circuit Troubleshooting CV CircuitTroubleshooting OVP Circuit Troubleshooting Down ProgrammerA4U4OUT Waveforms SET Voltage Vdc Node + Page Block Diagram Overview Autoranging PowerBlock Diagram Simplified Schematic Simplified Schematic Down Programmer DC-to-DC ConverterConstant-Voltage CV Circuit Pfet Control Signals Timing DiagramControl-Voltage Comparator Power-Limit ComparatorConstant-Current CC Circuit Overvoltage Protection OVP CircuitAC-Surge Dropout Detector Initial-Ramp CircuitPulse-Width Modulator PWM Bias Voltage DetectorDisplay Circuits Second-Delay CircuitPage Reference Designators Replaceable PartsDescription Abbreviations Ordering InformationCR3 Electrical PartsCR1 CR2XA2P2 XA2P1Mechanical Parts Control Board Assembly CR3 Page Page Page VR4 VR3VR5 DS1 CR5DS5 VR1 IC A/D Cmos 3-1/2 DGTVR2 Pfet NPN SIChassis Electrical TS1A4 Board Mechanical Parts A1TB1A2 Board Mechanical Parts A3 Board Mechanical PartsOption 240 240V Operation Option 220 220V OperationComponent Location and Circuit Diagrams Schematic Diagram Notes Pin locations for other semi-conductors are shown below Top View, Top Covers Removed Main Board A1 Component Location Control Board A2 Component Location Front-Panel Board A3 Component Location Power Mesh Board A4 Component Location Page Page General Information SpecificationsOption 002 Hardware Status Indicators Table A-1. Specifications, Option Remote ProgrammingInput Compliance Voltage ± Current Programming Enable Output Impedance 10.2 k ohm ± 5% Temperature CoefficientOn State logic low Remote Trip and Remote Reset TimingPower-on Preset Maximum Output Voltage logic high +Pard Typical Table A-1. Specifications, Option Pulse TimingBias Supplies DC Output Ratings 25C ± Short Circuit Output CurrentConnector Assembly Procedure InstallationOperation Figure A-1. Mating Connector AssemblyLocal/Remote Programming Resistance Voltage or Current Figure A-4. Calculating Value of Series Dropping Resistor Remote Resistance ProgrammingFigure A-5. Remote Resistance Programming Remote Monitoring Remote Control Status IndicatorsOvervoltage Remote ResetFigure A-8. Remote Control Power-On PresetMultiple Supply System Shutdown AC Dropout Buffer CircuitBias Supplies MaintenanceTroubleshooting Current Programming Troubleshooting Resistance and Voltage ProgrammingFigure A-11. Troubleshooting Current Programming of CV Mode Figure A-13. Troubleshooting Status Indicators Page REF. Desig Model no Description Table A-3. Replacement Parts100 101 VR9Definitions Indicator and Qualifier SymbolsOLD Symbol NEW Symbol Logic Symbols and Definitions 102Schematic Diagram Notes 103 Schematic NotesFigure A-15. Option 002 Board, Component Location 104 Schematic NotesFigure A-16. Option 002 Board, Schematic Diagram 105 Page Model 6028A Model 6023A107 108 From