Table A-1. Specifications, Option 002
Remote Programming
Resistance Programming: 0 to 4K ohm provides 0 to maximum rated voltage or current output.
Accuracy: | @25°C |
|
|
| CV: 0.5% + 12mV (6023A) | 0.5% | + 70mV (6028A) |
| CC: 1.0% + 110mA (6023A) | 1.0% | + 500mA (6028A) |
Voltage Programming: 0 to 5V provides 0 to maximum rated voltage or current output.
Accuracy: | @25°C |
|
| CV: 0.25% + 12mV (6023A) | 0.33% + 70mV (6028A) |
| CC: 0.30% + 110mA (6023A) | 0.36% ± 500mA (6028A) |
Current Programming: 0 to 2mA current sink provides 0 to maximum rated voltage or current output.
Accuracy:
0.43% ± 71mV (6028A)
0.50% + 500mV (6028A)
Input Compliance Voltage: ± 1V
Current Programming Enable:
Relays K2 (CV) and K1 (CC) are biased from the Control Isolator Bias input (See Remote Shutdown and OVP Clear).
Relay Bias Voltage: +4V minimum + 7V maximum
Relay Resistance: 500Ω ± 10%
Note
For Control Isolator Bias voltages greater than 7V, a series resistor must be used to maintain the relay bias voltage within specified limits.
Enabling either relay is accomplished by bringing CV or CC enable line to Control Isolator Bias common via a suitable driver; maximum driver
Output Voltage and Current Monitor: 0 to 5V output indicates 0 to maximum rated output voltage or current.
Accuracy: | @25°C |
|
| TC: 10ppm +0.2mV/°C |
| CV: 0.25% + 2mV (6023A) | 0.39% + 15mV (6028A) | ||
| CC: 0.30% + 15mA (6023A) | 0.36% + 20mA (6028A) | TC: 70ppm +1.5mA/°C | |
Output Impedance: 10.2 k ohm ± 5% |
|
|
| |
Temperature Coefficient: |
|
|
| |
| CV: 70 ppm/°C +600∝V/°C (6023A) | 12.5 ppm/°C +810∝V/°C (6028A) | ||
| CC: 100 ppm/°C + 2.0mA/°C (6023A) | 47 ppm/°C + 1.6mA/°C (6028A) |
Status Indicators:
Status Isolator Bias input (referred to Status Isolator Common).
80