Agilent Technologies AGILENT MODELS 6023A and 6028A service manual Operation

Page 84

Figure A-1. Mating Connector Assembly

Operation

The following paragraphs provide the operating instructions necessary to interface a 002-equipped power supply into an automated system. A brief description of some circuits is also provided. The unit is shipped for front-panel operation with mode switch settings as follows:

B1

B2

B3

B4

B5

B6

0

1

1

0

1

1

Before beginning, switch the power supply's rear panel MODE switches B1 through B6 to their correct positions for the programming source being used, (See Table A-2).

Next switch A1 and A2 also on the rear panel, to the correct program source function, See Figure A-2. All connections are made at the 37-pin rear panel connector J3, and can be wired directly into the mating connector supplied for this purpose.

84

Image 84
Contents Autoranging Certification Safety Summary Safety Symbol Definitions Printing HistoryTable of Contents Replaceable Parts Troubleshooting Circuit DiagramsSafety Considerations ScopeManual Revisions Item DescriptionCalibration Procedure IntroductionTest Equipment Required Operation Verification TestsType Required Characteristics USE Recommended Model Test Equipment RequiredInitial Setup 1KVACalibration Procedure MONVout IoutPerformance Tests Measurement TechniquesCR7 Current-Monitoring Resistor Setup Constant Voltage CV TestsBasic Test Setup RMS Measurement Test Setup, CV Pard Test Peak-To-Peak Measurement Test Setup, CV Pard Test 6023A 6028A KHz Noise, CV Peak-to-Peak PardLoad Transient Recovery Waveform Constant Current CC Tests CC Pard Test Setup Troubleshooting Initial Troubleshooting ProceduresControl Board Test Connector, A2J7 PIN no Signal NameVdc WAVEFORM/CONDITIONS SourceRepair and Replacement Electrostatic ProtectionA2 Control Board Removal A4 Power Mesh Board Removal Overall Troubleshooting ProcedureA3 Front-Panel Board Removal A1 Main Board RemovalUsing the Tables SetupNode MeasurementMain Troubleshooting Setup Main Troubleshooting SetupModified Mains Cord Set For Troubleshooting Troubleshooting No-Output Failures Front-Panel TroubleshootingPWM-ON PWM-OFF Defective Check Functional Circuits A2J7-26 A2J7-25Board Troubleshooting Bias Supplies Symptoms Defective Circuit Check ComponentsSymptoms Defective Check Functional Circuits Board Node + Measurement SourceNode + Measurement SourceNode + N0DE Power Section Blocks Troubleshooting AC-Turn-on CircuitsSetup Measurement Source Setup MeasurementTroubleshooting PWM & Clock Relay EnablePower Limit Troubleshooting DC-To-DC Converter + OUTPWM-ON PWM-OFFTroubleshooting CV Circuit Troubleshooting CC CircuitTroubleshooting Down Programmer Troubleshooting OVP CircuitA4U4OUT Waveforms SET Voltage Vdc Node + Page Autoranging Power Block Diagram OverviewBlock Diagram Simplified Schematic Simplified Schematic DC-to-DC Converter Down ProgrammerPfet Control Signals Timing Diagram Constant-Voltage CV CircuitPower-Limit Comparator Constant-Current CC CircuitOvervoltage Protection OVP Circuit Control-Voltage ComparatorInitial-Ramp Circuit Pulse-Width Modulator PWMBias Voltage Detector AC-Surge Dropout DetectorSecond-Delay Circuit Display CircuitsPage Replaceable Parts Reference DesignatorsOrdering Information Description AbbreviationsElectrical Parts CR1CR2 CR3XA2P1 XA2P2Mechanical Parts Control Board Assembly CR3 Page Page Page VR3 VR4VR5 CR5 DS1DS5 IC A/D Cmos 3-1/2 DGT VR1VR2 NPN SI PfetTS1 Chassis ElectricalA1TB1 A2 Board Mechanical PartsA3 Board Mechanical Parts A4 Board Mechanical PartsOption 220 220V Operation Option 240 240V OperationComponent Location and Circuit Diagrams Schematic Diagram Notes Pin locations for other semi-conductors are shown below Top View, Top Covers Removed Main Board A1 Component Location Control Board A2 Component Location Front-Panel Board A3 Component Location Power Mesh Board A4 Component Location Page Page Specifications General InformationOption 002 Hardware Table A-1. Specifications, Option Remote Programming Input Compliance Voltage ± Current Programming EnableOutput Impedance 10.2 k ohm ± 5% Temperature Coefficient Status IndicatorsRemote Trip and Remote Reset Timing Power-on PresetMaximum Output Voltage logic high + On State logic lowTable A-1. Specifications, Option Pulse Timing Bias Supplies DC Output Ratings 25C ±Short Circuit Output Current Pard TypicalInstallation Connector Assembly ProcedureFigure A-1. Mating Connector Assembly OperationLocal/Remote Programming Resistance Voltage or Current Remote Resistance Programming Figure A-4. Calculating Value of Series Dropping ResistorFigure A-5. Remote Resistance Programming Remote Monitoring Status Indicators Remote ControlRemote Reset OvervoltagePower-On Preset Figure A-8. Remote ControlAC Dropout Buffer Circuit Multiple Supply System ShutdownMaintenance Bias SuppliesTroubleshooting Resistance and Voltage Programming Troubleshooting Current ProgrammingFigure A-11. Troubleshooting Current Programming of CV Mode Figure A-13. Troubleshooting Status Indicators Page Table A-3. Replacement Parts REF. Desig Model no Description100 VR9 101Indicator and Qualifier Symbols OLD Symbol NEW SymbolLogic Symbols and Definitions 102 DefinitionsSchematic Notes Schematic Diagram Notes 103Schematic Notes Figure A-15. Option 002 Board, Component Location 104Figure A-16. Option 002 Board, Schematic Diagram 105 Page Model 6023A Model 6028A107 From 108