Agilent Technologies AGILENT MODELS 6023A and 6028A Modified Mains Cord Set For Troubleshooting

Page 30

As a convenience in implementing the troubleshooting setup, prepare cord sets as shown in Figure 3-2. This facilitates connecting the unit's input power receptacle to the external supply and connecting the bias transformer to the ac mains.

Figure 3-2. Modified Mains Cord Set For Troubleshooting

With the mains cord unplugged proceed as follows:

a.Remove the top cover and the inside cover as described on page 26. Set switch S4 (front-left corner of the A1 main board) in TEST position.

If switch is not in the TEST position and remains in the NORM position, completion of step e below will allow the unit to develop its 320Vdc bus voltage across PFETs A3Q3 and A3Q4 and will connect the ac mains voltage to the output of the external power supply. This will probably damage the external supply and is a shock hazard to you.

b.Install control board test connector onto the A2J3 card edge fingers.

c.Connect a 50Ω, 10W, load resistor to the unit's output terminals.

30

Image 30
Contents Autoranging Certification Safety Summary Safety Symbol Definitions Printing HistoryTable of Contents Replaceable Parts Safety Considerations TroubleshootingCircuit Diagrams ScopeManual Revisions Item DescriptionTest Equipment Required Calibration ProcedureIntroduction Operation Verification TestsType Required Characteristics USE Recommended Model Test Equipment RequiredInitial Setup 1KVACalibration Procedure MONVout IoutPerformance Tests Measurement TechniquesCR7 Current-Monitoring Resistor Setup Constant Voltage CV TestsBasic Test Setup RMS Measurement Test Setup, CV Pard Test Peak-To-Peak Measurement Test Setup, CV Pard Test 6023A 6028A KHz Noise, CV Peak-to-Peak PardLoad Transient Recovery Waveform Constant Current CC Tests CC Pard Test Setup Troubleshooting Initial Troubleshooting ProceduresVdc Control Board Test Connector, A2J7PIN no Signal Name WAVEFORM/CONDITIONS SourceRepair and Replacement Electrostatic ProtectionA2 Control Board Removal A3 Front-Panel Board Removal A4 Power Mesh Board RemovalOverall Troubleshooting Procedure A1 Main Board RemovalNode Using the TablesSetup MeasurementMain Troubleshooting Setup Main Troubleshooting SetupModified Mains Cord Set For Troubleshooting Troubleshooting No-Output Failures Front-Panel TroubleshootingPWM-ON PWM-OFF Defective Check Functional Circuits A2J7-26 A2J7-25Board Symptoms Defective Check Functional Circuits Board Troubleshooting Bias SuppliesSymptoms Defective Circuit Check Components Node + Measurement SourceNode + Measurement SourceNode + N0DE Setup Measurement Source Power Section BlocksTroubleshooting AC-Turn-on Circuits Setup MeasurementTroubleshooting PWM & Clock Relay EnablePower Limit PWM-ON Troubleshooting DC-To-DC Converter+ OUT PWM-OFFTroubleshooting CV Circuit Troubleshooting CC CircuitTroubleshooting Down Programmer Troubleshooting OVP CircuitA4U4OUT Waveforms SET Voltage Vdc Node + Page Autoranging Power Block Diagram OverviewBlock Diagram Simplified Schematic Simplified Schematic DC-to-DC Converter Down ProgrammerPfet Control Signals Timing Diagram Constant-Voltage CV CircuitOvervoltage Protection OVP Circuit Power-Limit ComparatorConstant-Current CC Circuit Control-Voltage ComparatorBias Voltage Detector Initial-Ramp CircuitPulse-Width Modulator PWM AC-Surge Dropout DetectorSecond-Delay Circuit Display CircuitsPage Replaceable Parts Reference DesignatorsOrdering Information Description AbbreviationsCR2 Electrical PartsCR1 CR3XA2P1 XA2P2Mechanical Parts Control Board Assembly CR3 Page Page Page VR3 VR4VR5 CR5 DS1DS5 IC A/D Cmos 3-1/2 DGT VR1VR2 NPN SI PfetTS1 Chassis ElectricalA3 Board Mechanical Parts A1TB1A2 Board Mechanical Parts A4 Board Mechanical PartsOption 220 220V Operation Option 240 240V OperationComponent Location and Circuit Diagrams Schematic Diagram Notes Pin locations for other semi-conductors are shown below Top View, Top Covers Removed Main Board A1 Component Location Control Board A2 Component Location Front-Panel Board A3 Component Location Power Mesh Board A4 Component Location Page Page Specifications General InformationOption 002 Hardware Output Impedance 10.2 k ohm ± 5% Temperature Coefficient Table A-1. Specifications, Option Remote ProgrammingInput Compliance Voltage ± Current Programming Enable Status IndicatorsMaximum Output Voltage logic high + Remote Trip and Remote Reset TimingPower-on Preset On State logic lowShort Circuit Output Current Table A-1. Specifications, Option Pulse TimingBias Supplies DC Output Ratings 25C ± Pard TypicalInstallation Connector Assembly ProcedureFigure A-1. Mating Connector Assembly OperationLocal/Remote Programming Resistance Voltage or Current Remote Resistance Programming Figure A-4. Calculating Value of Series Dropping ResistorFigure A-5. Remote Resistance Programming Remote Monitoring Status Indicators Remote ControlRemote Reset OvervoltagePower-On Preset Figure A-8. Remote ControlAC Dropout Buffer Circuit Multiple Supply System ShutdownMaintenance Bias SuppliesTroubleshooting Resistance and Voltage Programming Troubleshooting Current ProgrammingFigure A-11. Troubleshooting Current Programming of CV Mode Figure A-13. Troubleshooting Status Indicators Page Table A-3. Replacement Parts REF. Desig Model no Description100 VR9 101Logic Symbols and Definitions 102 Indicator and Qualifier SymbolsOLD Symbol NEW Symbol DefinitionsSchematic Notes Schematic Diagram Notes 103Schematic Notes Figure A-15. Option 002 Board, Component Location 104Figure A-16. Option 002 Board, Schematic Diagram 105 Page Model 6023A Model 6028A107 From 108