Chapter 3 |
| Hardware | ||
|
|
|
|
|
| Pin # | Signal | Description |
|
| 26 | LCDD10 | LVDS Channel Data Line 10 |
|
|
|
|
|
|
| 27, 28 | GND | Ground |
|
| 29 | LCDD04 | LVDS Channel Data Line 4 |
|
| 30 | LCDD07 | LVDS Channel Data Line 7 |
|
|
|
|
|
|
| 31 | LCDD05 | LVDS Channel Data Line 5 |
|
|
|
|
|
|
| 32 | LCDD06 | LVDS Channel Data Line 6 |
|
| 33, 34 | GND | Ground |
|
| 35 | LCDD01 | LVDS Channel Data Line 1 |
|
|
|
|
|
|
| 36 | LCDD03 | LVDS Channel Data Line 3 |
|
| 37 | LCDD00 | LVDS Channel Data Line 0 |
|
|
|
|
|
|
| 38 | LCDD02 | LVDS Channel Data Line 2 |
|
|
|
|
|
|
| 39, 40 | VCC | DC Power – +5V +/- 5% |
|
| 41 | FPDDC_DAT | Flat Panel I2C Data – I2C data interface to flat panel parameter EEPROM. |
|
| 42 | NC | Not connected (LTGIO) |
|
|
|
|
|
|
| 43 | FPDDC_CLK | Flat Panel I2C Clock – I2C clock interface to flat panel parameter EEPROM. |
|
| 44 | BLON* | Backlight On – Control signal for external flat panel backlight power. |
|
|
|
|
|
|
| 45 | NC | Not connected (BIASON) |
|
|
|
|
|
|
| 46 | DIGON | Digital Power On – This signal controls the digital flat panel power up. |
|
| 47 | COMP | Composite Analog Output |
|
|
|
|
|
|
| 48 | Y | TV Luminance for |
|
|
|
|
|
|
| 49 | NC | Not Connected (Composite Sync ) |
|
| 50 | C | TV Chrominance for |
|
| 51 | LPT/FLPY* | Parallel/Floppy Select – This input signal selects the parallel or floppy port |
|
|
|
| signal. If this signal is Low at boot time, the floppy drive is selected. If this |
|
|
|
| signal is High at boot time, the parallel port is selected. This state can not be |
|
|
|
| changed until the next boot cycle. |
|
| 52 | NC | Not Connected (Reserved) |
|
|
|
|
|
|
| 53 | VCC | DC Power – +5V +/- 5% |
|
| 54 | GND | Ground |
|
| 55 | Strobe* | Parallel Strobe* – This output signal is used to strobe data into the printer. |
|
|
|
| I/O pin in ECP/EPP mode. |
|
| 56 | AFD* | Parallel Auto Feed * – This is a output signal from the printer to automatically |
|
|
|
| feed one line after each line is printed. |
|
|
| DENSEL | Floppy Drive Density Select – This signal indicates if a low (250/300kBps) or |
|
|
|
| high (500/1kBps) data rate is selected. |
|
| 57 | NC | Not Connected (Reserved) |
|
| 58 | PD7 | Parallel Port Data 7 – This signal (0 to 7) provides a parallel port data signal |
|
|
|
| and is the printer data MSB. |
|
| 59 | IRRX | IR Receive Data (HPSIR or ASKIR) |
|
XTX 820 | Reference Manual | 43 |