Honeywell NETAXS-123 manual Battery, Suppressors

Page 18

Installing the NetAXS-123 Panels

Panel Components and Descriptions

2.4 Battery

For the NetAXS-123 Standard Enclosure panel, one CASIL CA1270, 12 VDC, 7A-hour sealed lead-acid battery (Honeywell order number 3-000066). The battery provides standby backup power, depending upon system configuration and activity. When AC is lost, the power supply automatically switches to the backup battery for continuous 12VDC power. Replace the battery every 2 to 2.5 years, or more often if the system has a high rate of backup use.

2.5 Suppressors

Two suppressors (HAS number S-4) are required for each door lock. One suppressor is installed on the panel control board, and the second must be installed at the door lock.

10www.honeywell.com

Image 18
Contents NetAXS-123 Page Contents RS-485 Connection via PCI-3 RS-485 Connection via NetAXS-123 List of Figures Page List of Tables Page Installing the NetAXS-123 Panels Access Control Overview IntroductionNetAXS-123 Overview NetAXS-123 Compact Enclosure Wiring and Components Panel Components and DescriptionsNetAXS-123 Standard Enclosure Panel Wiring and Components Supervised Input Wiring Board Configuration Terminal BlockSupervised Input Terminal Blocks Typical Supervised Input Wiring Diagram Supervised Tamper Terminal Blocks NetAXS-123 Input/Output Options NetAXS-123 Access Control Unit NetAXS-123 Add-On Board Board Readers Inputs/OutputsSupported Readers Readers Supported by NetAXS-123Series Reader Model Honeywell Part Number Power Supply Real-Time Clock ProtectionBattery SuppressorsInstallation Installing the Compact Enclosure PanelInstalling on a Wall Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing over a Gang Box Installing on a Flat Surface Installing the Standard Enclosure Panel Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the Add-On Board Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Wiring the Readers Wiring Readers to the Controller BoardFactory Default Configuration Settings for Door IN9 REX IO-TB5 Wiring Door Strikes Or S4 Setting DIP Switches and Jumpers Controller Board DIP Switch and Jumper SettingsNetAXS-123 SW1 DIP Switch Settings S7 a S8 b S9 b S10 SelectionOFF NetAXS-123 SW2 DIP Switch Settings S1a S2a SelectionNetAXS-123 Controller Board Jumpers ExternalAdd-On Board DIP Switch and Jumper Settings Normally Open Normally ClosedSetting the jumpers to configure the relay position 12V ExternalCommunications USB CommunicationsInstalling the NetAXS-123 Panels 2 RS-485 Communications RS-485 Configuration via N-485-PCI-3 RS-485 Configuration via NetAXS-123 Gateway Ethernet TCP/IP Configuration Ethernet TCP/IP CommunicationsSystem Configuration Ethernet ConnectionUSB Connection NetAXS-123 USB ConnectionRS-485 Connection via PCI-3 RS-485 Connection via PCI-3RS-485 Connection via NetAXS-123 Installing the NetAXS-123 Panels PCI3 M-56K Dial-up Modem, RS-485 Connection via Hub PCI-3 56K Dial-up Modem, RS-485 Connection via HubFiber Converter to RS-485 Connection via PCI-3 Fiber Converter to RS-485 Connection via PCI-3Fiber Converter to RS-485 Connection via NetAXS-123 Fiber Converter to RS-485 Connection via NetAXS-123Installing the NetAXS-123 Panels Ground only one Mixed Loops Relay Contacts Hardware SpecificationsPoE Power Limitations Reader InterfaceMechanical Device Element CurrentReader Wiring EnvironmentCable Basic Standalone Operation Card Read / Door Lock OperationDoor Egress / Door Lock / Door Status Operation Maintenance Troubleshooting Troubleshooting Problems and SolutionsProblem Solution Technical Support Normal Support HoursWeb This page is left blank for printing purposes Honeywell Access Systems