Honeywell NETAXS-123 manual NetAXS-123 Controller Board Jumpers, External

Page 47

Installing the NetAXS-123 Panels

Installation

Jumper Settings

The NetAXS-123 Controller Board provides two jumper sets, one each for output relay 1 and output relay 3. Each relay has two 3-pin jumpers associated with it. One jumper selects either external power (EXT) or self-whetted (on-board, +12V) power to be applied to the relay contact load. The other jumper is used to select Normally Open (NO) or Normally Closed (NC) relay contacts. There is a total of four 3-pin jumpers (two per relay) on the Controller Board.

Figure 7: NetAXS-123 Controller Board Jumpers

Each relay is associated with two jumpers. As shown below, a relay’s left jumper configures the relay’s load source (12VDC or External), and the right relay jumper configures the relay contact type (Normally Closed or Normally Open).

• Setting the jumpers to configure the power source:

12VDC

External

NetAXS-123 Access Control Unit Installation Guide, Document 800-05779, Revision A

39

Image 47
Contents NetAXS-123 Page Contents RS-485 Connection via PCI-3 RS-485 Connection via NetAXS-123 List of Figures Page List of Tables Page Installing the NetAXS-123 Panels NetAXS-123 Overview Access Control OverviewIntroduction Panel Components and Descriptions NetAXS-123 Compact Enclosure Wiring and ComponentsNetAXS-123 Standard Enclosure Panel Wiring and Components Supervised Input Terminal Blocks Supervised Input WiringBoard Configuration Terminal Block Supervised Tamper Terminal Blocks Typical Supervised Input Wiring DiagramBoard Readers Inputs/Outputs NetAXS-123 Access Control UnitNetAXS-123 Add-On Board NetAXS-123 Input/Output OptionsSeries Reader Model Honeywell Part Number Supported ReadersReaders Supported by NetAXS-123 Real-Time Clock Protection Power SupplySuppressors BatteryInstalling on a Wall InstallationInstalling the Compact Enclosure Panel Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing over a Gang Box Installing on a Flat Surface Installing the Standard Enclosure Panel Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Installing the Add-On Board Installing the NetAXS-123 Panels Installing the NetAXS-123 Panels Wiring Readers to the Controller Board Wiring the ReadersFactory Default Configuration Settings for Door IN9 REX IO-TB5 Wiring Door Strikes Or S4 Controller Board DIP Switch and Jumper Settings Setting DIP Switches and JumpersS7 a S8 b S9 b S10 Selection NetAXS-123 SW1 DIP Switch SettingsOFF S1a S2a Selection NetAXS-123 SW2 DIP Switch SettingsExternal NetAXS-123 Controller Board JumpersNormally Open Normally Closed Add-On Board DIP Switch and Jumper Settings12V External Setting the jumpers to configure the relay positionUSB Communications CommunicationsInstalling the NetAXS-123 Panels 2 RS-485 Communications RS-485 Configuration via N-485-PCI-3 RS-485 Configuration via NetAXS-123 Gateway Ethernet TCP/IP Communications Ethernet TCP/IP ConfigurationEthernet Connection System ConfigurationNetAXS-123 USB Connection USB ConnectionRS-485 Connection via PCI-3 RS-485 Connection via PCI-3RS-485 Connection via NetAXS-123 Installing the NetAXS-123 Panels PCI3 56K Dial-up Modem, RS-485 Connection via Hub M-56K Dial-up Modem, RS-485 Connection via Hub PCI-3Fiber Converter to RS-485 Connection via PCI-3 Fiber Converter to RS-485 Connection via PCI-3Fiber Converter to RS-485 Connection via NetAXS-123 Fiber Converter to RS-485 Connection via NetAXS-123Installing the NetAXS-123 Panels Ground only one Mixed Loops Reader Interface Hardware SpecificationsPoE Power Limitations Relay ContactsDevice Element Current MechanicalCable Reader WiringEnvironment Door Egress / Door Lock / Door Status Operation Basic Standalone OperationCard Read / Door Lock Operation Maintenance Problem Solution TroubleshootingTroubleshooting Problems and Solutions Web Technical SupportNormal Support Hours This page is left blank for printing purposes Honeywell Access Systems

NETAXS-123 specifications

The Honeywell NETAXS-123 is an advanced access control solution designed to enhance security and efficiency for various facilities, including commercial buildings, educational institutions, and healthcare facilities. It provides a versatile platform that integrates cutting-edge technologies to simplify access management while maintaining a high level of protection.

One of the standout features of the NETAXS-123 is its web-based interface, which allows administrators to manage access from anywhere with an internet connection. This cloud-based accessibility is a significant advantage for organizations that require real-time monitoring and control over their security systems. Users can easily configure access rights, generate reports, and monitor system events through a user-friendly dashboard that minimizes the need for extensive training.

The NETAXS-123 supports a range of authentication methods, including key cards, biometric readers, and mobile credentials, ensuring that organizations can implement the best solution for their specific security needs. The system facilitates multiple entry points, enabling different access levels for various personnel, which helps in maintaining strict control over sensitive areas.

Another feature is its scalability. The NETAXS-123 can accommodate small installations with just a few doors and is easily expandable to support larger operations with dozens of access points. This flexibility makes it ideal for growing organizations that anticipate changes in their access control needs.

The system is equipped with advanced reporting capabilities, allowing administrators to generate detailed activity logs and audit trails. These logs play a crucial role in investigating incidents and ensuring compliance with industry regulations and standards, making the NETAXS-123 a reliable choice for organizations focused on security and accountability.

In terms of connectivity, the NETAXS-123 integrates seamlessly with existing IT infrastructures, supporting Ethernet and Wi-Fi connectivity options. This compatibility ensures smooth operation and easy integration with other security systems like CCTV and alarm monitoring.

The hardware components of the NETAXS-123 are built with durable materials, ensuring longevity and reliable performance, even in demanding environments. With features such as power over Ethernet (PoE), the system simplifies installation by reducing the need for separate power sources, allowing for more streamlined deployments.

In conclusion, the Honeywell NETAXS-123 combines advanced features, user-friendly technology, and robust security measures to deliver an effective access control solution. Its scalability, diverse authentication methods, and real-time management capabilities make it a top choice for organizations looking to enhance their security infrastructure.