Agilent Technologies 85032B/E 50 manual Replaceable Parts for the 85032E Calibration Kit

Page 44

Replaceable Parts

Introduction

Table 6-2 Replaceable Parts for the 85032E Calibration Kit

Item No.

Description

Qty Per Kit

Agilent Part Number

 

 

 

 

 

Calibration Devices (50Ω Type-N)

 

 

 

 

 

1

Male broadband load

1

00909-60009

 

 

 

 

2

Male combination open/short

1

85032-60011

 

 

 

 

 

Calibration Kit Storage Case

 

 

 

 

 

3

Case (without foam pad set)

1

9211-1582

 

 

 

 

4

Foam pad set

1

85023-80005

 

 

 

 

5

Kit identification label

1

85032-80014

 

 

 

 

 

Protective End Caps for Connectors

 

 

 

 

 

6

Male end cap for type-N and 7 mm

as

1401-0214

 

 

required

 

 

 

 

 

 

Miscellaneous Items

 

 

 

 

 

 

7

User’s and service guide

1

85032-90020

 

 

 

 

Figure 6-2 Replaceable Parts for the 85032E Calibration Kit

6-4

85032B/E

Image 44
Contents User’s and Service Guide Agilent Part Number Print Date JulyDocumentation Warranty Contents Troubleshooting General Information Kit Contents Calibration Kit OverviewInstallation of the Calibration Definitions Calibration DefinitionsAdapters OptionsIncoming Inspection Serial Number Record for 85032E Recording the Device Serial NumbersSerial Number Record for 85032B Clarifying the Sex of a Connector Preventive MaintenanceSpecifications Temperature-What to Watch Out For Environmental RequirementsEnvironmental Requirements Parameter LimitsMechanical Characteristics Pin DepthPin Depth Limit Electrical Specifications Supplemental Electrical CharacteristicsElectrical Specifications for 50Ω Type-N Devices Supplemental Electrical CharacteristicsElectrical Specifications 85032B/E Use, Maintenance, and Care of the Devices ESD Protection Setup Electrostatic DischargeWhat Causes Connector Wear? Visual InspectionLook for Obvious Defects and Damage First Inspect the Mating Plane SurfacesUse Compressed Air or Nitrogen Cleaning ConnectorsInspect Female Connectors Clean the Mating Plane Surfaces ReinspectGaging Connectors Connector Gage AccuracyWhen to Gage Connectors Reading the Connector GageGaging Procedures Gaging Male Type-N ConnectorsGaging Male Type-N Connectors Gaging Female Type-N Connectors Gaging Female Type-N Connectors How to Make a Connection Final Connection Using a Torque WrenchConnections Preliminary ConnectionWrench Positions Connecting the Two-Piece Female Open How to Separate a Connection Handling and StorageHandling and Storage 85032B/E Performance Verification Introduction How Agilent Verifies the Devices in This KitWhere to Send a Kit for Recertification RecertificationLimited Recertification Option How Often to RecertifyRecertification 85032B/E Troubleshooting Troubleshooting Process Troubleshooting FlowchartReturning a Kit or Device to Agilent Contacting AgilentReturning a Kit or Device to Agilent 85032B/E Replaceable Parts Protective End Caps for Connectors Replaceable Parts for the 85032B Calibration KitAdapters included with Option 100b Calibration Kit Storage CaseReplaceable Parts for the 85032B Calibration Kit Replaceable Parts for the 85032E Calibration Kit Connector Cleaning Supplies Replaceable Parts-Items Not Included in the Calibration KitWrenches ESD Protective DevicesIntroduction 85032B/E Standard Definitions Class Standard Class Label Standard Class AssignmentsTable A-1 Standard Class Assignments Blank Form Table A-2 Standard Class Assignments Blank FormCalibration Kit Label Class Standard ClassSetting the System Impedance Nominal Standard DefinitionsTable A-3 Standard Definitions System Z a = 50 Ω Calibration Kit LabelType Min MaxStandardb Offset Freq Number Type 10C0× 10C1× PsDelay Table A-4 Standard Definitions Blank FormSystem Z 0 a = 10C2× 10C3×Index Index-2 85032B/E Index-3