Agilent Technologies 85032B/E 50 manual Index-2 85032B/E

Page 54

Index

connecting, 3-14disconnecting, 3-14

frequency specifications, 2-5

frequency range, 2-5,4-3

G

gage connector

dial, 3-7

handling, 3-8,3-10master, 3-8,3-10,6-5reading, 3-7zeroing, 3-8,3-10

gage master

part numbers, 6-5using, 3-8,3-10

gages, 1-3gaging

female connectors, 3-10male connectors, 3-8procedures, 3-8

gaging connectors, 3-6when to do, 3-7

H

handling, 3-15humidity, 2-2

I

impedance system, A-4

incoming inspection, 1-4inspection

damage, 3-3defects, 3-3

female connectors, 3-4incoming, 1-4mating plane, 3-3visual, 3-3

isopropyl alcohol

as cleaning solvent, 3-4

K

kit contents, 1-2overview, 1-2

return to Agilent, 5-3serial number, 1-5

L

label calibration, 4-3

part number, 6-5limited calibration, 4-3

limited calibration, 1-3requesting, 4-3

loads broadband, 1-2

M

maintenance, 3-2preventive, 1-6

maintenance of devices, 1-6making connections, 3-12manual

part number, 6-5mating plane

conductor, 2-3connector, 3-5

mating plane inspection, 3-3mating plane surfaces, 3-5mechanical characteristics, 2-3mechanical integrity, 2-3

N

nitrogen, 3-4

nominal standard definitions, A-4numbers

serial, 1-5recording, 1-5

O

open-end wrench, 1-3,3-15part number, 6-5

opens, 1-2

opens and shorts, 1-2options, 1-3ordering parts, 6-2

P

part numbers, 6-2parts

ordering, 6-2replaceable, 6-2

required but not supplied, 6-2performance verification, 4-2

fail, 5-2

permanently stored calibration definitions, 1-3

pin depth, 2-3definition of, 2-3effect on electrical

specifications, 2-4importance of, 2-4observed limits, 2-4typical values, 2-4

preventive maintenance, 1-6protrusion

center conductor, 3-7conductor, 2-3

R

reading connector gage, 3-7recertification, 4-3

how often?, 4-3interval, 4-3limited, 4-3what’s included, 4-3

where to send your kit, 4-3recession

center conductor, 3-7conductor, 2-3

regulations environmental, 3-5

replaceable parts, 6-2requirements

environmental, 2-2return loss

specifications, 2-5return, kit or device, 5-3

S

serial numbers, 1-5devices, 1-5recording, 1-5

service, 5-2

service tag, 1-4,4-3,5-3sex

connector, 1-6shipment

damage, 1-4

verifying complete, 1-4shorts, 1-2specifications, 2-2

altitude, 2-2certification, 2-5electrical, 2-5environmental, 2-2frequency, 2-5humidity, 2-2

pin depth, 2-4return loss, 2-5temperature, 2-2verifying, 4-2

standard class assignments, A-2blank form, A-3

standard definitions, A-4,A-6blank form, A-6nominal, A-4

standards calibration, 2-5NIST, 2-5,4-3

static discharge, 3-2sticker

calibration, 4-3storage, 3-15

altitude, 2-2humidity, 2-2

Index-2

85032B/E

Image 54
Contents User’s and Service Guide Agilent Part Number Print Date JulyDocumentation Warranty Contents Troubleshooting General Information Kit Contents Calibration Kit OverviewAdapters Installation of the Calibration DefinitionsCalibration Definitions OptionsIncoming Inspection Recording the Device Serial Numbers Serial Number Record for 85032BSerial Number Record for 85032E Clarifying the Sex of a Connector Preventive MaintenanceSpecifications Environmental Requirements Temperature-What to Watch Out ForEnvironmental Requirements Parameter LimitsMechanical Characteristics Pin DepthPin Depth Limit Electrical Specifications for 50Ω Type-N Devices Electrical SpecificationsSupplemental Electrical Characteristics Supplemental Electrical CharacteristicsElectrical Specifications 85032B/E Use, Maintenance, and Care of the Devices ESD Protection Setup Electrostatic DischargeLook for Obvious Defects and Damage First What Causes Connector Wear?Visual Inspection Inspect the Mating Plane SurfacesCleaning Connectors Inspect Female ConnectorsUse Compressed Air or Nitrogen Clean the Mating Plane Surfaces ReinspectGaging Connectors Connector Gage AccuracyWhen to Gage Connectors Reading the Connector GageGaging Procedures Gaging Male Type-N ConnectorsGaging Male Type-N Connectors Gaging Female Type-N Connectors Gaging Female Type-N Connectors Connections How to Make a ConnectionFinal Connection Using a Torque Wrench Preliminary ConnectionWrench Positions Connecting the Two-Piece Female Open How to Separate a Connection Handling and StorageHandling and Storage 85032B/E Performance Verification Introduction How Agilent Verifies the Devices in This KitLimited Recertification Option Where to Send a Kit for RecertificationRecertification How Often to RecertifyRecertification 85032B/E Troubleshooting Troubleshooting Process Troubleshooting FlowchartReturning a Kit or Device to Agilent Contacting AgilentReturning a Kit or Device to Agilent 85032B/E Replaceable Parts Adapters included with Option 100b Protective End Caps for ConnectorsReplaceable Parts for the 85032B Calibration Kit Calibration Kit Storage CaseReplaceable Parts for the 85032B Calibration Kit Replaceable Parts for the 85032E Calibration Kit Wrenches Connector Cleaning SuppliesReplaceable Parts-Items Not Included in the Calibration Kit ESD Protective DevicesIntroduction 85032B/E Standard Definitions Standard Class Assignments Table A-1 Standard Class AssignmentsClass Standard Class Label Calibration Kit Label Class Blank FormTable A-2 Standard Class Assignments Blank Form Standard ClassSetting the System Impedance Nominal Standard DefinitionsType Table A-3 Standard DefinitionsSystem Z a = 50 Ω Calibration Kit Label Min MaxSystem Z 0 a = Standardb Offset Freq Number Type 10C0× 10C1× PsDelayTable A-4 Standard Definitions Blank Form 10C2× 10C3×Index Index-2 85032B/E Index-3