Agilent Technologies 85032B/E 50 manual Recording the Device Serial Numbers

Page 9

General Information

Recording the Device Serial Numbers

Recording the Device Serial Numbers

In addition to the kit serial number, the devices in this kit are individually serialized (serial numbers are labeled onto the body of each device). Record these serial numbers in Table 1-1for the 85032B and Table 1-2for the 85032E. Recording the serial numbers will prevent confusing the devices in this kit with similar devices in other kits.

Table 1-1 Serial Number Record for 85032B

Device

Serial Number

 

 

Calibration kit

_______________________________

Male broadband load

_______________________________

Female broadband load

_______________________________

Male open

_______________________________

Female open

_______________________________

Male short

_______________________________

Female short

_______________________________

Type-N-male to 7-mm adapter

_______________________________

Type-N-male to 7-mm adapter

_______________________________

Type-N-female to 7-mm adapter

_______________________________

Type-N-female to 7-mm adapter

_______________________________

 

 

Table 1-2 Serial Number Record for 85032E

Device

Serial Number

 

 

Calibration kit

_______________________________

Male broadband load

_______________________________

Male combination open/short

_______________________________

 

 

85032B/E

1-5

Image 9
Contents Agilent Part Number Print Date July User’s and Service GuideDocumentation Warranty Contents Troubleshooting General Information Calibration Kit Overview Kit ContentsCalibration Definitions Installation of the Calibration DefinitionsAdapters OptionsIncoming Inspection Recording the Device Serial Numbers Serial Number Record for 85032BSerial Number Record for 85032E Preventive Maintenance Clarifying the Sex of a ConnectorSpecifications Environmental Requirements Temperature-What to Watch Out ForEnvironmental Requirements Parameter LimitsPin Depth Mechanical CharacteristicsPin Depth Limit Supplemental Electrical Characteristics Electrical SpecificationsElectrical Specifications for 50Ω Type-N Devices Supplemental Electrical CharacteristicsElectrical Specifications 85032B/E Use, Maintenance, and Care of the Devices Electrostatic Discharge ESD Protection SetupVisual Inspection What Causes Connector Wear?Look for Obvious Defects and Damage First Inspect the Mating Plane SurfacesCleaning Connectors Inspect Female ConnectorsUse Compressed Air or Nitrogen Reinspect Clean the Mating Plane SurfacesConnector Gage Accuracy Gaging ConnectorsReading the Connector Gage When to Gage ConnectorsGaging Male Type-N Connectors Gaging ProceduresGaging Male Type-N Connectors Gaging Female Type-N Connectors Gaging Female Type-N Connectors Final Connection Using a Torque Wrench How to Make a ConnectionConnections Preliminary ConnectionWrench Positions Connecting the Two-Piece Female Open Handling and Storage How to Separate a ConnectionHandling and Storage 85032B/E Performance Verification How Agilent Verifies the Devices in This Kit IntroductionRecertification Where to Send a Kit for RecertificationLimited Recertification Option How Often to RecertifyRecertification 85032B/E Troubleshooting Troubleshooting Flowchart Troubleshooting ProcessContacting Agilent Returning a Kit or Device to AgilentReturning a Kit or Device to Agilent 85032B/E Replaceable Parts Replaceable Parts for the 85032B Calibration Kit Protective End Caps for ConnectorsAdapters included with Option 100b Calibration Kit Storage CaseReplaceable Parts for the 85032B Calibration Kit Replaceable Parts for the 85032E Calibration Kit Replaceable Parts-Items Not Included in the Calibration Kit Connector Cleaning SuppliesWrenches ESD Protective DevicesIntroduction 85032B/E Standard Definitions Standard Class Assignments Table A-1 Standard Class AssignmentsClass Standard Class Label Table A-2 Standard Class Assignments Blank Form Blank FormCalibration Kit Label Class Standard ClassNominal Standard Definitions Setting the System ImpedanceSystem Z a = 50 Ω Calibration Kit Label Table A-3 Standard DefinitionsType Min MaxTable A-4 Standard Definitions Blank Form Standardb Offset Freq Number Type 10C0× 10C1× PsDelaySystem Z 0 a = 10C2× 10C3×Index Index-2 85032B/E Index-3