Agilent Technologies 85032B/E 50 manual Incoming Inspection

Page 8

General Information

Incoming Inspection

Incoming Inspection

Verify that the shipment is complete by referring to Figure 6-1or Figure 6-2.

Check for damage. The foam-lined storage case provides protection during shipping.

If the case or any device appears damaged, or if the shipment is incomplete, contact Agilent. See Table 5-1 on page 5-3. Agilent will arrange for repair or replacement of incomplete or damaged shipments without waiting for a settlement from the transportation company.

When you send the kit or device to Agilent, include a service tag (found near the end of this manual) with the following information:

your company name and address

the name of a technical contact person within your company, and the person's complete phone number

the model number and serial number of the kit

the part number and serial number of the device

the type of service required

a detailed description of the problem

1-4

85032B/E

Image 8
Contents User’s and Service Guide Agilent Part Number Print Date JulyDocumentation Warranty Contents Troubleshooting General Information Kit Contents Calibration Kit OverviewInstallation of the Calibration Definitions Calibration DefinitionsAdapters OptionsIncoming Inspection Serial Number Record for 85032E Recording the Device Serial NumbersSerial Number Record for 85032B Clarifying the Sex of a Connector Preventive MaintenanceSpecifications Temperature-What to Watch Out For Environmental RequirementsEnvironmental Requirements Parameter LimitsMechanical Characteristics Pin DepthPin Depth Limit Electrical Specifications Supplemental Electrical CharacteristicsElectrical Specifications for 50Ω Type-N Devices Supplemental Electrical CharacteristicsElectrical Specifications 85032B/E Use, Maintenance, and Care of the Devices ESD Protection Setup Electrostatic DischargeWhat Causes Connector Wear? Visual InspectionLook for Obvious Defects and Damage First Inspect the Mating Plane SurfacesUse Compressed Air or Nitrogen Cleaning ConnectorsInspect Female Connectors Clean the Mating Plane Surfaces ReinspectGaging Connectors Connector Gage AccuracyWhen to Gage Connectors Reading the Connector GageGaging Procedures Gaging Male Type-N ConnectorsGaging Male Type-N Connectors Gaging Female Type-N Connectors Gaging Female Type-N Connectors How to Make a Connection Final Connection Using a Torque WrenchConnections Preliminary ConnectionWrench Positions Connecting the Two-Piece Female Open How to Separate a Connection Handling and StorageHandling and Storage 85032B/E Performance Verification Introduction How Agilent Verifies the Devices in This KitWhere to Send a Kit for Recertification RecertificationLimited Recertification Option How Often to RecertifyRecertification 85032B/E Troubleshooting Troubleshooting Process Troubleshooting FlowchartReturning a Kit or Device to Agilent Contacting AgilentReturning a Kit or Device to Agilent 85032B/E Replaceable Parts Protective End Caps for Connectors Replaceable Parts for the 85032B Calibration KitAdapters included with Option 100b Calibration Kit Storage CaseReplaceable Parts for the 85032B Calibration Kit Replaceable Parts for the 85032E Calibration Kit Connector Cleaning Supplies Replaceable Parts-Items Not Included in the Calibration KitWrenches ESD Protective DevicesIntroduction 85032B/E Standard Definitions Class Standard Class Label Standard Class AssignmentsTable A-1 Standard Class Assignments Blank Form Table A-2 Standard Class Assignments Blank FormCalibration Kit Label Class Standard ClassSetting the System Impedance Nominal Standard DefinitionsTable A-3 Standard Definitions System Z a = 50 Ω Calibration Kit LabelType Min MaxStandardb Offset Freq Number Type 10C0× 10C1× PsDelay Table A-4 Standard Definitions Blank FormSystem Z 0 a = 10C2× 10C3×Index Index-2 85032B/E Index-3