Agilent Technologies 85032B/E 50 Replaceable Parts-Items Not Included in the Calibration Kit

Page 45

Replaceable Parts

Introduction

Table 6-3 Replaceable Parts—Items Not Included in the Calibration Kit

Item No.

Description

Qty

Agilent Part Number

 

 

 

 

 

Connector Gagesa (Type-N)

 

 

1

Gage set (includes items listed below)

1

85054-60049

 

 

 

 

2

Female gage

1

85054-60050

 

 

 

 

3

Female gage master

1

85054-60052

 

 

 

 

4

Male gage

1

85054-60051

 

 

 

 

5

Male gage master

1

85054-60053

 

 

 

 

6

Centering bead (2 supplied with gage set)

1

85054-80028

 

 

 

 

 

Wrenches

 

 

 

 

 

 

7

3/4 in, 135 N-cm (12 in-lb) torque wrench

1

8710-1766

 

 

 

 

8

1/2 in and 9/16 in open-end wrench

1

8710-1770

 

 

 

 

9

3/4 in open-end wrench

1

8720-0011

 

 

 

 

 

ESD Protective Devices

 

 

 

 

 

 

10

Grounding wrist strap

1

9300-1367

 

 

 

 

11

5 ft grounding cord for wrist strap

1

9300-0980

 

 

 

 

12

2 ft by 4 ft conductive table mat with 15 ft grounding wire

1

9300-0797

 

 

 

 

13

ESD heel strap

1

9300-1308

 

 

 

 

 

Connector Cleaning Supplies

 

 

 

 

 

 

14

Isopropyl alcohol

30 ml

8500-5344

 

 

 

 

15

Foam tipped cleaning swabs

100

9301-1243

 

 

 

 

a. To ensure you choose the correct gage, refer to, “Clarifying the Sex of a Connector” on page 1-6.

85032B/E

6-5

Image 45
Contents Agilent Part Number Print Date July User’s and Service GuideDocumentation Warranty Contents Troubleshooting General Information Calibration Kit Overview Kit ContentsCalibration Definitions Installation of the Calibration DefinitionsAdapters OptionsIncoming Inspection Recording the Device Serial Numbers Serial Number Record for 85032BSerial Number Record for 85032E Preventive Maintenance Clarifying the Sex of a ConnectorSpecifications Environmental Requirements Temperature-What to Watch Out ForEnvironmental Requirements Parameter LimitsPin Depth Mechanical CharacteristicsPin Depth Limit Supplemental Electrical Characteristics Electrical SpecificationsElectrical Specifications for 50Ω Type-N Devices Supplemental Electrical CharacteristicsElectrical Specifications 85032B/E Use, Maintenance, and Care of the Devices Electrostatic Discharge ESD Protection SetupVisual Inspection What Causes Connector Wear?Look for Obvious Defects and Damage First Inspect the Mating Plane SurfacesCleaning Connectors Inspect Female ConnectorsUse Compressed Air or Nitrogen Reinspect Clean the Mating Plane SurfacesConnector Gage Accuracy Gaging ConnectorsReading the Connector Gage When to Gage ConnectorsGaging Male Type-N Connectors Gaging ProceduresGaging Male Type-N Connectors Gaging Female Type-N Connectors Gaging Female Type-N Connectors Final Connection Using a Torque Wrench How to Make a ConnectionConnections Preliminary ConnectionWrench Positions Connecting the Two-Piece Female Open Handling and Storage How to Separate a ConnectionHandling and Storage 85032B/E Performance Verification How Agilent Verifies the Devices in This Kit IntroductionRecertification Where to Send a Kit for RecertificationLimited Recertification Option How Often to RecertifyRecertification 85032B/E Troubleshooting Troubleshooting Flowchart Troubleshooting ProcessContacting Agilent Returning a Kit or Device to AgilentReturning a Kit or Device to Agilent 85032B/E Replaceable Parts Replaceable Parts for the 85032B Calibration Kit Protective End Caps for Connectors Adapters included with Option 100b Calibration Kit Storage CaseReplaceable Parts for the 85032B Calibration Kit Replaceable Parts for the 85032E Calibration Kit Replaceable Parts-Items Not Included in the Calibration Kit Connector Cleaning SuppliesWrenches ESD Protective DevicesIntroduction 85032B/E Standard Definitions Standard Class Assignments Table A-1 Standard Class AssignmentsClass Standard Class Label Table A-2 Standard Class Assignments Blank Form Blank FormCalibration Kit Label Class Standard ClassNominal Standard Definitions Setting the System ImpedanceSystem Z a = 50 Ω Calibration Kit Label Table A-3 Standard DefinitionsType Min MaxTable A-4 Standard Definitions Blank Form Standardb Offset Freq Number Type 10C0× 10C1× PsDelaySystem Z 0 a = 10C2× 10C3×Index Index-2 85032B/E Index-3