a/d/s/ iSeries manual Reset Setup Submenu, Rate Setup Submenu, Cycle Time Submenu

Page 41

RESET SETUP SUBMENU:

Press d 33) Display flashes 1st digit of the previous I REST Reset value. Press b & c 34) Press b and c buttons to enter a new “Reset” value. Press d 35) Display shows STRD stored message momentarily and then

advances to RATE only, if it was changed, otherwise press a to advance to RATE Rate Setup Submenu.

Reset unit is in seconds 0-3999.

RATE SETUP SUBMENU:

Press d 36) Display flashes 1st digit of previous D RATE Rate value. Press b & c 37) Press b and c buttons to enter a new RATE value.

Press d 38) Display shows STRD stored message momentarily and then

advances to the CYCL only, if it was changed, otherwise press a to advance to CYCL Cycle Time submenu for RTD and

Thermocouple types.

Rate unit is in seconds 000.0-399.9.

CYCLE TIME SUBMENU:

Press d 39) Display flashes 1st digit of the previous CYCL Cycle Time value.

Press b & c 40) Press b and c buttons to enter a new “Cycle Time” value. (1 to 199 seconds)

Press d 41) Display shows STRD stored message momentarily and then advances to DPNG only, if it was changed, otherwise press a to advance to DPNG Damping Factor Submenu.

A Cycle Time selected between 1 and 199 seconds determines the total On/Off time of each proportional cycle. For example, a 15 second cycle time means that every 15 seconds the output will turn on for part or all of the cycle. For Relay control outputs, do not select a cycle time of less than 7 seconds or the relays’ lifetime will be shortened. For a cycle time of less than 7 seconds select SSR or DC pulse. Use an external SSR with the DC pulse option for higher currents (higher than 1 Amp).

37

Image 41
Contents Newport Electronics,Inc Newport Electronics,Inc Table of Contents Input Properties Factory Preset Values Flow Chart for Alarm 1 Menu Flow Chart for Alarm 2 MenuList of Figures List of TablesTIP Description Part IntroductionEMC Considerations Safety ConsiderationsBefore You Begin Optional Remote Programmer Front Panel Part SetupFront Panel Connections PowerInput OutputMain Power Connections Fuse Requirement see specifications Electrical Installation Power ConnectionsThermocouple Input Thermocouple Wiring Hookup TC Wire Color ChartOhm Wiring Hookup 3 Two/Three/Four-Wire RTDProcess Voltage Process CurrentIsolated Analog Output Wiring Hookup Wiring Outputs10 Snubber Circuits Wiring Hookup 13 Excitation Output Part Operation Configuration Mode IntroductionButton Function in Configuration Mode Flow Chart for ID and Set Points Menu ConfigurationID Number Entering Your NON-DEFAULT Full Security ID NumberEntering Your NON-DEFAULT SETPOINT/ID Security ID Number Setpoint Set PointsInput Type Menu Configuration MenuEnter Configuration Menu Enter Input Type Menu Input Type ThermocoupleThermocouple Submenu Thermocouple TypesRTD Submenu Input Type RTDRTD Types RTD Value SubmenuInput Type Process Reading Configuration MenuProcess Submenu Process TypesTemperature Unit Submenu Enter Reading Configuration MenuDecimal Point Submenu Filter Constant SubmenuINPUT/READING Scale and Offset Submenu Reading Configuration If Process was selectedRange Conversion Number Conversion TableEnter Alarm 1 Menu AlarmAlarm 1 LATCH/UNLATCH Submenu Alarm 1 ENABLE/DISABLE SubmenuAlarm 1 ABSOLUTE/DEVIATION Submenu Active Submenu Contact Closure SubmenuAlarm 1 HI Value Submenu Alarm ENABLE/DISABLE AT Power onAlarm 1 LOW Value Submenu Enter Alarm 2 Menu Loop Break Time/Field Calibration Loop Break ENABLE/DISABLE SubmenuEnter Loop Break Time Menu Loop Break Time Value SubmenuThermocouple Field Calibration Submenu Reading Adjust SubmenuSetpoint Deviation ENABLE/DISABLE Submenu Output Flow Chart for OutputMINIMUM/PERCENT LOW Submenu Enter Output 1 MenuSelf Submenu Action Type Submenu MAXIMUM/PERCENT High SubmenuControl Type Output Relay, SSR, or Pulse Anti Integral Submenu Auto PID SubmenuProportional Band Submenu Start Auto Tune PIDCycle Time Submenu Reset Setup SubmenuRate Setup Submenu Deadband Submenu Damping Factor SubmenuCURRENT/VOLTAGE Submenu Analog Output RetransmissionEnter Analog Output Menu OUT ReadingSoak ENABLE/DISABLE Submenu Ramp ENABLE/DISABLE SubmenuRamp & Soak Enter Ramp and Soak MenuSoak Value Submenu Ramp Value SubmenuEnter ID Code Menu Entering or Changing Your NON-DEFAULT ID CodeID Code SETPOINT/ID Security Level Submenu Entering or Changing Your Default ID CodeFull Security Level Submenu Communication Option 12 Flow Chart for Communication OptionCommunication Parameters Submenu Enter Communication Option MenuBaud Submenu Parity SubmenuBUS Format Submenu Stop BIT SubmenuModbus Protocol Submenu Line Feed SubmenuData Separation Character Submenu Data Flow Mode SubmenuCommunication Interface Standard Submenu Data Format Submenu Alarm Status SubmenuMain Reading Submenu Peak Value SubmenuAddress Value Submenu Address Setup SubmenuTransmit Time Interval Submenu Transmit Time Interval Value SubmenuDisplay Color Selection Alarm 1 Display Color SubmenuEnter Display Color Selection Menu Normal Color Display SubmenuExample Alarm 2 Display Color SubmenuDisplay Colors change sequences Green RED AmberAmber RED Green Part Specifications Control Output ControlSSR CommunicationsGeneral ExcitationInsulation Input Type Range Accuracy Input PropertiesFactory preset value Part 5 Factory Preset ValuesDisplay Color Colr Measurement Category Part CE Approvals InformationPage Page Page Warranty/Disclaimer M4165/N/0206