a/d/s/ iSeries manual Part 5 Factory Preset Values, Factory preset value

Page 62

PART 5 FACTORY PRESET VALUES

Table 5.1 Factory preset value

MENU ITEMS

FACTORY PRESET VALUES

NOTES

Set Point 1 (SP1)

000.0

 

Set Point 2 (SP2)

000.0

 

Input:

 

 

Input Type (INPT)

TC, type K

 

Reading Configuration (RDG):

 

 

Decimal Point (DEC.P)

FFF.F

 

Temperature unit (TEMP)

°F

 

Filter value (FLTR)

0004

 

Alarm 1 & 2:

 

 

Alarm 1 (ALR1)

Disable (DSBL)

 

Alarm 2 (ALR2)

Enable (ENBL)

 

Absolute/Deviation (ABSO/DEV)

Absolute (ABSO)

 

Latch/Unlatch (LTCH/UNLT)

Unlatch (UNLT)

 

Contact Closure (CT.CL)

Normally Open (N.O.)

 

Active (ACTV)

Above (ABOV)

 

Alarm At Power On (A.P.ON)

Disable (DSBL)

Alarm 1 only

Alarm Low (ALR.L)

-100.0

 

Alarm High (ALR.H)

400.0

 

LOOP:

 

 

Loop Break Time (LOOP)

Disable (DSBL)

 

Loop Value (B.TIM)

00:59

 

Reading Adjust Value (R.ADJ)

000.0

 

Setpoint Deviation (SP.dV)

Disable (DSBL)

 

OUTPUT 1:

 

 

Self (SELF)

Disabled (DSBL)

 

% Low Value (%LO)

0000

 

% High Value (%HI)

0099

 

Control Type (CTRL)

On/Off

 

Action Type (ACTN)

Reverse (RVRS)

 

Dead Band (DEAD)

020.0

 

PID Auto (AUTO)

Disable (DSBL)

 

Anti Integral (ANTI)

Disable (DSBL)

 

Proportion Value (PROP)

020.0

 

Reset Value (REST)

0180

 

Rate Value (RATE)

0000

 

Cycle Value (CYCL)

0007

 

Damping Factor (DPNG)

0003

 

ANALOG OUTPUT (Retransmission)

 

 

Analog Output (ANLG)

Enabled (ENBL)

 

Current/Voltage (CURR/VOLT)

Voltage (VOLT)

 

Scale and Offset

Reading: 0 - 999.9 cts, Output: 0 - 10 V

 

 

 

58

Image 62
Contents Newport Electronics,Inc Newport Electronics,Inc Table of Contents List of Figures Flow Chart for Alarm 1 Menu Flow Chart for Alarm 2 MenuInput Properties Factory Preset Values List of TablesTIP Part Introduction DescriptionSafety Considerations EMC ConsiderationsBefore You Begin Part Setup Optional Remote Programmer Front PanelInput PowerFront Panel Connections OutputElectrical Installation Power Connections Main Power Connections Fuse Requirement see specificationsThermocouple Wiring Hookup TC Wire Color Chart Thermocouple Input3 Two/Three/Four-Wire RTD Ohm Wiring HookupProcess Current Process VoltageWiring Outputs Isolated Analog Output Wiring Hookup10 Snubber Circuits Wiring Hookup 13 Excitation Output Part Operation Configuration Mode IntroductionButton Function in Configuration Mode Menu Configuration Flow Chart for ID and Set PointsID Number Entering Your NON-DEFAULT Full Security ID NumberEntering Your NON-DEFAULT SETPOINT/ID Security ID Number Set Points SetpointInput Type Menu Configuration MenuEnter Configuration Menu Thermocouple Submenu Input Type ThermocoupleEnter Input Type Menu Thermocouple TypesRTD Types Input Type RTDRTD Submenu RTD Value SubmenuProcess Submenu Reading Configuration MenuInput Type Process Process TypesDecimal Point Submenu Enter Reading Configuration MenuTemperature Unit Submenu Filter Constant SubmenuReading Configuration If Process was selected INPUT/READING Scale and Offset SubmenuConversion Table Range Conversion NumberAlarm Enter Alarm 1 MenuAlarm 1 LATCH/UNLATCH Submenu Alarm 1 ENABLE/DISABLE SubmenuAlarm 1 ABSOLUTE/DEVIATION Submenu Contact Closure Submenu Active SubmenuAlarm 1 HI Value Submenu Alarm ENABLE/DISABLE AT Power onAlarm 1 LOW Value Submenu Enter Alarm 2 Menu Enter Loop Break Time Menu Loop Break ENABLE/DISABLE SubmenuLoop Break Time/Field Calibration Loop Break Time Value SubmenuThermocouple Field Calibration Submenu Reading Adjust SubmenuSetpoint Deviation ENABLE/DISABLE Submenu Flow Chart for Output OutputMINIMUM/PERCENT LOW Submenu Enter Output 1 MenuSelf Submenu Action Type Submenu MAXIMUM/PERCENT High SubmenuControl Type Output Relay, SSR, or Pulse Auto PID Submenu Anti Integral SubmenuStart Auto Tune PID Proportional Band SubmenuCycle Time Submenu Reset Setup SubmenuRate Setup Submenu Damping Factor Submenu Deadband SubmenuCURRENT/VOLTAGE Submenu Analog Output RetransmissionEnter Analog Output Menu Reading OUTRamp & Soak Ramp ENABLE/DISABLE SubmenuSoak ENABLE/DISABLE Submenu Enter Ramp and Soak MenuRamp Value Submenu Soak Value SubmenuEnter ID Code Menu Entering or Changing Your NON-DEFAULT ID CodeID Code SETPOINT/ID Security Level Submenu Entering or Changing Your Default ID CodeFull Security Level Submenu 12 Flow Chart for Communication Option Communication OptionBaud Submenu Enter Communication Option MenuCommunication Parameters Submenu Parity SubmenuModbus Protocol Submenu Stop BIT SubmenuBUS Format Submenu Line Feed SubmenuData Separation Character Submenu Data Flow Mode SubmenuCommunication Interface Standard Submenu Main Reading Submenu Alarm Status SubmenuData Format Submenu Peak Value SubmenuTransmit Time Interval Submenu Address Setup SubmenuAddress Value Submenu Transmit Time Interval Value SubmenuEnter Display Color Selection Menu Alarm 1 Display Color SubmenuDisplay Color Selection Normal Color Display SubmenuDisplay Colors change sequences Alarm 2 Display Color SubmenuExample Green RED AmberAmber RED Green Part Specifications SSR ControlControl Output CommunicationsGeneral ExcitationInsulation Input Properties Input Type Range AccuracyPart 5 Factory Preset Values Factory preset valueDisplay Color Colr Part CE Approvals Information Measurement CategoryPage Page Page Warranty/Disclaimer M4165/N/0206