a/d/s/ iSeries manual Part Setup, Optional Remote Programmer Front Panel

Page 9

PART 2

SETUP

Refer to the Quick Start Guide for assembly and disassembly instructions.

2.1 Optional Remote Programmer Front Panel

Figure 2.1 Optional Remote Programmer Front Panel

Table 2.1

Optional Remote Programmer Front Panel Annunciators

1Output 1/Setpoint 1/ Alarm 1 indicator

2 Output 2/Setpoint 2/ Alarm 2 indicator

°C

°C unit indicator

°F

°F unit indicator

a

Changes display to Configuration Mode and

 

advances through menu items*

b

Used in Program Mode and Peak Recall*

c

Used in Program Mode and Valley Recall*

d

Accesses submenus in Configuration Mode

 

and stores selected values*

* See Part 3 Operation: Configuration Mode

5

Image 9
Contents Newport Electronics,Inc Newport Electronics,Inc Table of Contents Input Properties Factory Preset Values Flow Chart for Alarm 1 Menu Flow Chart for Alarm 2 MenuList of Figures List of TablesTIP Description Part IntroductionEMC Considerations Safety ConsiderationsBefore You Begin Optional Remote Programmer Front Panel Part SetupFront Panel Connections PowerInput OutputMain Power Connections Fuse Requirement see specifications Electrical Installation Power ConnectionsThermocouple Input Thermocouple Wiring Hookup TC Wire Color ChartOhm Wiring Hookup 3 Two/Three/Four-Wire RTDProcess Voltage Process CurrentIsolated Analog Output Wiring Hookup Wiring Outputs10 Snubber Circuits Wiring Hookup 13 Excitation Output Operation Configuration Mode Introduction Button Function in Configuration ModePart Flow Chart for ID and Set Points Menu ConfigurationEntering Your NON-DEFAULT Full Security ID Number Entering Your NON-DEFAULT SETPOINT/ID Security ID NumberID Number Setpoint Set PointsConfiguration Menu Enter Configuration MenuInput Type Menu Enter Input Type Menu Input Type ThermocoupleThermocouple Submenu Thermocouple TypesRTD Submenu Input Type RTDRTD Types RTD Value SubmenuInput Type Process Reading Configuration MenuProcess Submenu Process TypesTemperature Unit Submenu Enter Reading Configuration MenuDecimal Point Submenu Filter Constant SubmenuINPUT/READING Scale and Offset Submenu Reading Configuration If Process was selectedRange Conversion Number Conversion TableEnter Alarm 1 Menu AlarmAlarm 1 ENABLE/DISABLE Submenu Alarm 1 ABSOLUTE/DEVIATION SubmenuAlarm 1 LATCH/UNLATCH Submenu Active Submenu Contact Closure SubmenuAlarm ENABLE/DISABLE AT Power on Alarm 1 LOW Value SubmenuAlarm 1 HI Value Submenu Enter Alarm 2 Menu Loop Break Time/Field Calibration Loop Break ENABLE/DISABLE SubmenuEnter Loop Break Time Menu Loop Break Time Value SubmenuReading Adjust Submenu Setpoint Deviation ENABLE/DISABLE SubmenuThermocouple Field Calibration Submenu Output Flow Chart for OutputEnter Output 1 Menu Self SubmenuMINIMUM/PERCENT LOW Submenu MAXIMUM/PERCENT High Submenu Control Type Output Relay, SSR, or PulseAction Type Submenu Anti Integral Submenu Auto PID SubmenuProportional Band Submenu Start Auto Tune PIDReset Setup Submenu Rate Setup SubmenuCycle Time Submenu Deadband Submenu Damping Factor SubmenuAnalog Output Retransmission Enter Analog Output MenuCURRENT/VOLTAGE Submenu OUT ReadingSoak ENABLE/DISABLE Submenu Ramp ENABLE/DISABLE SubmenuRamp & Soak Enter Ramp and Soak MenuSoak Value Submenu Ramp Value SubmenuEntering or Changing Your NON-DEFAULT ID Code ID CodeEnter ID Code Menu Entering or Changing Your Default ID Code Full Security Level SubmenuSETPOINT/ID Security Level Submenu Communication Option 12 Flow Chart for Communication OptionCommunication Parameters Submenu Enter Communication Option MenuBaud Submenu Parity SubmenuBUS Format Submenu Stop BIT SubmenuModbus Protocol Submenu Line Feed SubmenuData Flow Mode Submenu Communication Interface Standard SubmenuData Separation Character Submenu Data Format Submenu Alarm Status SubmenuMain Reading Submenu Peak Value SubmenuAddress Value Submenu Address Setup SubmenuTransmit Time Interval Submenu Transmit Time Interval Value SubmenuDisplay Color Selection Alarm 1 Display Color SubmenuEnter Display Color Selection Menu Normal Color Display SubmenuExample Alarm 2 Display Color SubmenuDisplay Colors change sequences Green RED AmberAmber RED Green Part Specifications Control Output ControlSSR CommunicationsExcitation InsulationGeneral Input Type Range Accuracy Input PropertiesFactory preset value Part 5 Factory Preset ValuesDisplay Color Colr Measurement Category Part CE Approvals InformationPage Page Page Warranty/Disclaimer M4165/N/0206