a/d/s/ iSeries manual Entering or Changing Your Default ID Code, Full Security Level Submenu

Page 48

ENTERING OR CHANGING YOUR (DEFAULT) ID CODE:

Enter ID menu (Repeat steps from 1 to 3).

Press d 10) Display advances to CH.ID Change ID Code Submenu. Press d 11) Display shows 0000 message with flashing 1st digit.

If you want to change your default “ID Code” you can do it now, otherwise press a and menu will skip to FULL Full Security Submenu.

Press b & c 12) Press b and c buttons to enter your new “ID Code” number. Press d 13) Display shows STRD stored message momentarily and then

advances to the FULL Full Security Submenu.

FULL SECURITY LEVEL SUBMENU:

Press

d

14)

Display flashes ENBL Enable or DSBL Disable.

Press

b

15) Scroll through the available selections: “Enable” or “Disable”.

Press d

16)

Display shows STRD stored message momentarily and then

 

 

advances to SP.ID Setpoint/ID Submenu.

 

 

If "Full" Security Level is "Enabled" and the user attempts to

 

 

enter the Main Menu, they will be prompted for an ID Code. The

 

 

 

 

ID Code should be correct to enter the instrument Menu item.

SETPOINT/ID SECURITY LEVEL SUBMENU:

 

 

This Security Level can be functional only if FULL Security

 

 

Level is Disabled.

 

 

Press

d

17)

Display flashes ENBL Enable or DSBL Disable.

Press

b

18) Scroll through the available selections: “Enable” or “Disable”.

Press d

19)

Display shows STRD stored message momentarily and then

 

 

advances to COMM Communication Submenu.

If "Setpoint/ID" Security Level is "Enabled" and the user attempts to advance into the CNFG Configuration Menu, he will be prompted for ID Code number. The ID Code should be correct to proceed into the Configuration Menu, otherwise display will show an Error and skip to the Run Mode.

If “Full” and “Setpoint/ID” Security Levels are "Disabled", the ID code will be “Disabled” and user will not be asked for ID Code to enter the Menu items (“ID” Submenu will not show up in “ID/Setpoint” Menu).

44

Image 48
Contents Newport Electronics,Inc Newport Electronics,Inc Table of Contents Flow Chart for Alarm 1 Menu Flow Chart for Alarm 2 Menu Input Properties Factory Preset ValuesList of Figures List of TablesTIP Part Introduction DescriptionSafety Considerations EMC ConsiderationsBefore You Begin Part Setup Optional Remote Programmer Front PanelPower Front Panel ConnectionsInput OutputElectrical Installation Power Connections Main Power Connections Fuse Requirement see specificationsThermocouple Wiring Hookup TC Wire Color Chart Thermocouple Input3 Two/Three/Four-Wire RTD Ohm Wiring HookupProcess Current Process VoltageWiring Outputs Isolated Analog Output Wiring Hookup10 Snubber Circuits Wiring Hookup 13 Excitation Output Operation Configuration Mode Introduction Button Function in Configuration ModePart Menu Configuration Flow Chart for ID and Set PointsEntering Your NON-DEFAULT Full Security ID Number Entering Your NON-DEFAULT SETPOINT/ID Security ID NumberID Number Set Points SetpointConfiguration Menu Enter Configuration MenuInput Type Menu Input Type Thermocouple Enter Input Type MenuThermocouple Submenu Thermocouple TypesInput Type RTD RTD SubmenuRTD Types RTD Value SubmenuReading Configuration Menu Input Type ProcessProcess Submenu Process TypesEnter Reading Configuration Menu Temperature Unit SubmenuDecimal Point Submenu Filter Constant SubmenuReading Configuration If Process was selected INPUT/READING Scale and Offset SubmenuConversion Table Range Conversion NumberAlarm Enter Alarm 1 MenuAlarm 1 ENABLE/DISABLE Submenu Alarm 1 ABSOLUTE/DEVIATION SubmenuAlarm 1 LATCH/UNLATCH Submenu Contact Closure Submenu Active SubmenuAlarm ENABLE/DISABLE AT Power on Alarm 1 LOW Value SubmenuAlarm 1 HI Value Submenu Enter Alarm 2 Menu Loop Break ENABLE/DISABLE Submenu Loop Break Time/Field CalibrationEnter Loop Break Time Menu Loop Break Time Value SubmenuReading Adjust Submenu Setpoint Deviation ENABLE/DISABLE SubmenuThermocouple Field Calibration Submenu Flow Chart for Output OutputEnter Output 1 Menu Self SubmenuMINIMUM/PERCENT LOW Submenu MAXIMUM/PERCENT High Submenu Control Type Output Relay, SSR, or PulseAction Type Submenu Auto PID Submenu Anti Integral SubmenuStart Auto Tune PID Proportional Band SubmenuReset Setup Submenu Rate Setup SubmenuCycle Time Submenu Damping Factor Submenu Deadband SubmenuAnalog Output Retransmission Enter Analog Output MenuCURRENT/VOLTAGE Submenu Reading OUTRamp ENABLE/DISABLE Submenu Soak ENABLE/DISABLE SubmenuRamp & Soak Enter Ramp and Soak MenuRamp Value Submenu Soak Value SubmenuEntering or Changing Your NON-DEFAULT ID Code ID CodeEnter ID Code Menu Entering or Changing Your Default ID Code Full Security Level SubmenuSETPOINT/ID Security Level Submenu 12 Flow Chart for Communication Option Communication OptionEnter Communication Option Menu Communication Parameters SubmenuBaud Submenu Parity SubmenuStop BIT Submenu BUS Format SubmenuModbus Protocol Submenu Line Feed SubmenuData Flow Mode Submenu Communication Interface Standard SubmenuData Separation Character Submenu Alarm Status Submenu Data Format SubmenuMain Reading Submenu Peak Value SubmenuAddress Setup Submenu Address Value SubmenuTransmit Time Interval Submenu Transmit Time Interval Value SubmenuAlarm 1 Display Color Submenu Display Color SelectionEnter Display Color Selection Menu Normal Color Display SubmenuAlarm 2 Display Color Submenu ExampleDisplay Colors change sequences Green RED AmberAmber RED Green Part Specifications Control Control OutputSSR CommunicationsExcitation InsulationGeneral Input Properties Input Type Range AccuracyPart 5 Factory Preset Values Factory preset valueDisplay Color Colr Part CE Approvals Information Measurement CategoryPage Page Page Warranty/Disclaimer M4165/N/0206