Connections with any Existing Network System

ERROR

ALARM

STOP

PLAY

REC

RESET STILL SEQUENCE

ALARM

1

2

3

4

5

 

ESC

COPY 2

HDD

 

 

 

 

 

MENU

PAUSE REV FWD

SKIP

TIMER

6

7

8

9

0

 

SET

 

OPERATE

Digital Disk Recorder WJ-RT 208

IP Address: 192.168.0.88

LAN cable

Subnet Mask: 255.255.255.0

(Not provided: 10BASE-T/100BASE-Tx, Category 5, Straight)

Gateway Address: 192.168.0.1

 

 

 

 

 

HUB/Router

 

IP Address: 192.168.0.1

 

Subnet Mask: 255.255.255.0

Microsoft

 

Windowsxp

LAN

 

PC/AT Compatible

Microsoft

Windowsxp

IP Address: 192.168.0.x (x except 0, 1, 88, 255)

 

Subnet Mask: 255.255.255.0

 

Gateway Address: 192.168.0.1

 

 

PC/AT Compatible

Connections with a Broadband WAN Network

ERROR

ALARM

STOP

PLAY

REC

RESET STILL SEQUENCE

ALARM

1

2

3

4

5

 

ESC

COPY 2

HDD

 

 

 

 

 

MENU

PAUSE REV FWD

SKIP

TIMER

6

7

8

9

0

 

SET

 

OPERATE

Digital Disk Recorder WJ-RT 208

Server Port: 2000 (changeable)

Alarm Port: 4000 (changeable)

Broadband router A

Forward (WAN DVR)

UDP Port: 9998 (fixed)

TCP Port: 2000 (depends on the recorder settings)

WAN

Microsoft

Windowsxp

PC/AT Compatible

Broadband router B

Forward (WAN PC)

UDP Port: 999 (fixed)

TCP Port: 4000 (depends on the recorder settings)

Notes:

1.Broadband router A can only connect one WJ-RT208. (Each WJ-RT208 should be assigned a Global IP address.)

2.Broadband router B can only connect one PC/AT compatible machine. (Each compatible machine should be assigned a global IP address.)

Caution: The number of clients that can be connected to each WJ-RT208 is defined in the next table. According to differences in the network communication protocol, the number of clients that can be connected can differ. In the next table, the num- ber of clients that can be connected is defined for the TCP/UDP protocol and the MCAST protocol, independently of each other.

User type

TCP/UDP

MCAST

Manager

1 person

1 person

 

 

 

Remote monitoring

8 persons

Unlimited in the same subnet

 

 

 

Remote playback/net backup

1 person

1 person

 

 

 

Frame play

4 persons

Frame play not available

 

 

 

Remote talk

1 person

1 person

 

 

 

17

Image 17
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Limitation of Liability Disclaimer of WarrantyAbout These Operating Instructions PrecautionsTrademarks and Registered Trademarks Contents Preface FeaturesFront View Major Operating Controls & Their Functions@6Copy Connector Copy 6Cancel Button ESC↓ Down button ← Left buttonRear View Installing the Hard Disk InstallationPlaces to avoid About mountingMaster HDD of IDE port HDD connected to IDE port Slave HDD Page Basic System System Composition and ConnectionsExample for Basic System Connections Basic ConnectionWJ-RT208 Connection with RS485 CameraNetwork System Connection with External HDD For Data BackupExample for Network System Connection Direct PC ConnectionUser type Connections with any Existing Network SystemConnections with a Broadband WAN Network Connection with PS·Data systems When connecting a single unit with a controllerWhen connecting multiple units with a controller When using WJ-MP204 When using WJ-SX150RS485 Connection Pin No Signal Operation RemarksDIP Switch Setting Turning the Power On Setup ProceduresPreparation User RegistrationBasic Operation of the Menu Main menu Submenu Example Menu type2005-01-28 Cancel Turning the Power OffModification of the System Time Time & Date YYYY-MM-DD HhmmssScreen Operation OperationManual Recording Playback of Recorded ImagePlayback the record Operations for EventsEvent type Action at an eventCamera Control Cancellation of alarmPTZ Setup PTZ Select Preset Information Panning/Tilting RS485 SetupAuto function Auto Pan, etc PanasonicTo display the camera setting menu To register preset position of camerasZoom FocusOutlined functions Computer configurationControl this Unit with a PC Setting Item Description SetupSystem Management System MAN Operation for Various SettingsNtsc Picture adjustment Picture Adjust Reboot system Reboot SystemDisk information Disk Information Time & date Time & DateTimer recording Timer REC Recording & event setup REC & EventRecord search Search Terminal recording Terminal RECVideo motion detector recording VMD REC Time Per File 015 Min Cancel VMD Area Setup Area SetupSetup enabled range 005 Record length Record LengthCamera setup Camera Setup PTZ setup PTZ SetupPreset position information Preset INFORMA- Tion PTZ selection PTZ SelectTCP Communication setup CommunicaNetwork setup Network Setup Data port setup Data Port Setup RS485 setup RS485 SetupReport System LOG Event LOG Oldest Data Information Report ReportSystem log System LOG User information User Information User level setup User Level SetupEvent log Event LOG Oldest data information Oldest Data InforDo you really want to lock keyboard ? Cancel Password PasswordData management Data MANAGE- Ment Online user information Online User INFORMA- TionSearch and Playback Backup by External HDDChannel No Start End Event Only 2004-10-22 2004-10-272004-10-10 Data Management Factory Default BackupDisk Management All data will be deleted Will you continue ? CancelHDD formatting Disk FormatRecovery of hard disk index Returning the Configuration to the Default SettingsScreen in a certain channel System Screen ExplanationsOrdinary screen 9-split screen System Management System Management Setup Menu Parameters and Initial Setup ValuesTimer Recording Timer REC Recording & Event Setup REC & EventRecording Search Search Terminal Recording Terminal RECPTZ Setup PTZ Setup Communication Setup Communication Setup Camera Setup Camera SetupNetwork Setup Network Setup RS485 Setup RS485 SetupSystem Log System LOG Report ReportEvent Log Event LOG Oldest Data Information Oldest Data InformationData Management Data Management User Information User InformationOperation using the WV-CU650 Operation using the system controllerAvailable only during playback Problem Check item/remedy TroubleshootingBasic Specifications SpecificationsGeneral Input/OutputTable of Recording Length Standard AccessoriesPage Ns0306-1046 3TR004320BAA