Panasonic WJ-RT208 manual PTZ Setup PTZ Setup

Page 52

3.3 VMD Setup (VMD REC)

Setting item

Default setting

Available values

"Channel No."

1

1

-

8

 

 

 

 

 

"Sensitivity"

10

01

-

99

 

 

 

 

 

"Area Setup"

*

 

 

 

 

 

 

 

"Alarm Output"

0

0

-

3

 

 

 

 

 

"(Alarm Time)"

030

000

-

999

 

 

 

 

 

"Rec. Interval"

060

030

-

999

 

 

 

 

 

"PTZ Preset"

000

000

-

256

 

 

 

"Rec. Quality"

"Normal"

"SP Fine/Fine/Good/Normal/Extended"

 

 

 

"(Frame Rate)"

"Full"

"Full/1/2F/1/4F/1/8F/1/16F"

 

 

 

"(Stream Type)"

"CBR"

"CBR/VBR"

 

 

 

"Period1"

00:00

00:00 - 24:00

 

 

 

 

24:00

00:00 - 24:00

 

 

 

 

"Off"

"Off/On"

 

 

 

"Period2"

00:00

00:00 - 24:00

 

 

 

 

24:00

00:00 - 24:00

 

 

 

 

"Off"

"Off/On"

 

 

 

 

 

Notes:

The parameters for this unit can be defined for each channel.

The underlined parameters will not be copied when the channel copy is performed. * At the default, no area is selected. Up to 140 (14 x 10) areas are available.

3.4 Recording Length (RECORD LENGTH)

Setting item

Default setting

Available values

"Record Length"

015

005 - 240

 

 

 

3.5 Audio Selection (AUDIO SELECT)

Setting item

Default setting

Available values

"Audio1 - 8"

"Audio select"

"Selected/not selected"

 

 

 

4. PTZ Setup (PTZ SETUP)

4.1 PTZ Selection (PTZ SELECT)

Setting item

Default setting

Available values

"Cam1 - 8"

"Not selected"

"Selected/not selected"

 

 

 

4.2 Preset Information (PRESET INFORMATION)

Setting item

Default setting

Available values

"Camera"

1

1

- 8

 

 

 

 

"Preset"

001

001

- 256

 

 

 

 

52

Image 52
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Disclaimer of Warranty Limitation of LiabilityTrademarks and Registered Trademarks PrecautionsAbout These Operating Instructions Contents Features PrefaceMajor Operating Controls & Their Functions Front View6Cancel Button ESC @6Copy Connector Copy↓ Down button ← Left buttonRear View Installation Installing the Hard DiskPlaces to avoid About mountingMaster HDD of IDE port HDD connected to IDE port Slave HDD Page System Composition and Connections Basic SystemExample for Basic System Connections Basic ConnectionConnection with RS485 Camera WJ-RT208Connection with External HDD For Data Backup Network SystemExample for Network System Connection Direct PC ConnectionConnections with a Broadband WAN Network Connections with any Existing Network SystemUser type When connecting multiple units with a controller When connecting a single unit with a controllerConnection with PS·Data systems When using WJ-SX150 When using WJ-MP204Pin No Signal Operation Remarks RS485 ConnectionDIP Switch Setting Setup Procedures Turning the Power OnPreparation User RegistrationBasic Operation of the Menu Menu type Main menu Submenu ExampleTurning the Power Off 2005-01-28 CancelModification of the System Time Time & Date YYYY-MM-DD HhmmssOperation Screen OperationManual Recording Playback of Recorded ImageOperations for Events Playback the recordEvent type Action at an eventPTZ Setup PTZ Select Preset Information Cancellation of alarmCamera Control RS485 Setup Panning/TiltingAuto function Auto Pan, etc PanasonicTo register preset position of cameras To display the camera setting menuZoom FocusControl this Unit with a PC Computer configurationOutlined functions Setup Setting Item DescriptionOperation for Various Settings System Management System MANNtsc Reboot system Reboot System Picture adjustment Picture AdjustDisk information Disk Information Time & date Time & DateRecording & event setup REC & Event Timer recording Timer RECRecord search Search Terminal recording Terminal RECVideo motion detector recording VMD REC VMD Area Setup Area Setup Time Per File 015 Min CancelSetup enabled range 005 Record length Record LengthPTZ setup PTZ Setup Camera setup Camera SetupPreset position information Preset INFORMA- Tion PTZ selection PTZ SelectNetwork setup Network Setup Communication setup CommunicaTCP RS485 setup RS485 Setup Data port setup Data Port SetupSystem log System LOG Report ReportReport System LOG Event LOG Oldest Data Information User level setup User Level Setup User information User InformationEvent log Event LOG Oldest data information Oldest Data InforPassword Password Do you really want to lock keyboard ? CancelData management Data MANAGE- Ment Online user information Online User INFORMA- TionBackup by External HDD Search and PlaybackChannel No Start End Event Only 2004-10-22 2004-10-27Data Management Factory Default Backup 2004-10-10All data will be deleted Will you continue ? Cancel Disk ManagementHDD formatting Disk FormatReturning the Configuration to the Default Settings Recovery of hard disk indexOrdinary screen 9-split screen System Screen ExplanationsScreen in a certain channel Setup Menu Parameters and Initial Setup Values System Management System ManagementRecording & Event Setup REC & Event Timer Recording Timer RECRecording Search Search Terminal Recording Terminal RECPTZ Setup PTZ Setup Camera Setup Camera Setup Communication Setup Communication SetupNetwork Setup Network Setup RS485 Setup RS485 SetupReport Report System Log System LOGEvent Log Event LOG Oldest Data Information Oldest Data InformationUser Information User Information Data Management Data ManagementOperation using the system controller Operation using the WV-CU650Available only during playback Troubleshooting Problem Check item/remedySpecifications Basic SpecificationsGeneral Input/OutputStandard Accessories Table of Recording LengthPage Ns0306-1046 3TR004320BAA