Panasonic WJ-RT208 Camera Control, Cancellation of alarm, PTZ Setup PTZ Select Preset Information

Page 28

When an event occurs, the monitoring images of its channel are displayed in the spot screen.

The spot screen is set up with the menu specified below.

"WJ-RT208 SETUP MENU" - "SYSTEM MANAGEMENT" - "SYSTEM SETUP" - "Alarm Spot" - "On"

Recording when an event occurs

When there is an alarm, recording is automatically car- ried out during the setup time. In the state of Video Loss, no recording is carried out. This time setting is made with the menu shown below.

"WJ-RT208 SETUP MENU" - "REC & EVENT" - "TERMI- NAL REC" and "WJ-RT208 SETUP MENU" - "REC & EVENT" - "VMD REC" - "Period1" or "Period2" - "On"

Buzzer

The [ALARM] indicator blinks when an alarm is activat- ed, and this buzzer sounds.

The buzzer is set up with the menu specified below. "WJ-RT208 SETUP MENU] - "SYSTEM MANAGEMENT" - "SYSTEM SETUP" - "Alarm Buzz" - "On"

An alarm signal output is generated from the TERMI- NAL/CONTROL port of the rear panel to the port of the preset number. The [ALARM] indicator blinks. The out- put port number of Alarm Output is set up with the menu specified below.

"WJ-RT208 SETUP MENU" - "REC & EVENT" - "TERMI- NAL REC" - "Alarm Output" and "WJ-RT208 SETUP MENU" - "REC & EVENT" - "VMD REC" - "Alarm Output"

Camera turning direction preset position

The camera preset position is set up with the menu specified below.

"WJ-RT208 SETUP MENU" - "REC & EVENT" - "TERMI- NAL REC" - "VMD REC" - "PTZ Preset" or "WJ-RT208 SETUP MENU" - "REC & EVENT" - "VMD REC" - "PTZ Preset"

In regard to camera’s preset position setup, refer to "2.5.6 Register preset position of cameras" on page 30.

Notes:

1.This recorder is designed to start recording upon termi- nal input or on motion detection. When an alarm occurs in the process of recording images from the channel for which "TERMINAL REC" and "VMD REC" are set, only alarm actions such as event recording or event status display will be performed. Image quality for recording (Rec. Quality), frame rate and stream type will not auto- matically be changed.

2.If another alarm occurs again in the same channel with- in the time period that has been preset with "Alarm Time", the alarm is stopped after the lapse of the preset time period. (The alarm time period is not extended.)

3.Even though an alarm occurs, no automatic recording is carried out unless "Period1" or "Period2" of "TERMI- NAL REC" and "VMD REC" has been set at "On".

4.Information about external alarms is directly sent to the PC through the network. It has no relation to the "TER- MINAL REC" and "VMD REC" setting at the recorder. Please refer to <<Network Operating Instructions.pdf>> on the CD-ROM.

5.When "Full" is selected for "Frame Rate", performing playback, recording of all channels and transmission of all channels of Net Client in parallel for many hours may stop image processing. In this case, recording will be continued, though few frames may be dropped.

2.4.3 Cancellation of alarm

When the [ALARM RESET] button is pressed, the alarm is cancelled. The [ALARM] indicator goes off.

Notes:

1.Recording is continued even though this alarm is can- celled.

2.The alarm cannot be cancelled while a menu is dis- played.

Close the menu, and then press the [ALARM RESET] button to cancel the alarm.

2.5 Camera Control

(1)Press the [MENU] button. "WJ-RT208 SETUP MENU" appears.

WJ-RT208 SETUP MENU

SYSTEM MANAGEMENT

SEARCH

REC&EVENT SETUP

PTZ SETUP

CAMERA SETUP

COMMUNICATION SETUP

REPORT

USER INFORMATION

DATA MANAGEMENT

(2)Move the cursor to "PTZ SETUP" and press the [SET] button.

The "PTZ SETUP" menu appears.

PTZ SETUP

PTZ SELECT

PRESET INFORMATION

28

Image 28
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Disclaimer of Warranty Limitation of LiabilityTrademarks and Registered Trademarks PrecautionsAbout These Operating Instructions Contents Features PrefaceMajor Operating Controls & Their Functions Front View6Cancel Button ESC @6Copy Connector Copy↓ Down button ← Left buttonRear View Installation Installing the Hard DiskPlaces to avoid About mountingMaster HDD of IDE port HDD connected to IDE port Slave HDD Page System Composition and Connections Basic SystemExample for Basic System Connections Basic ConnectionConnection with RS485 Camera WJ-RT208Connection with External HDD For Data Backup Network SystemExample for Network System Connection Direct PC ConnectionConnections with a Broadband WAN Network Connections with any Existing Network SystemUser type When connecting multiple units with a controller When connecting a single unit with a controllerConnection with PS·Data systems When using WJ-SX150 When using WJ-MP204Pin No Signal Operation Remarks RS485 ConnectionDIP Switch Setting Setup Procedures Turning the Power OnPreparation User RegistrationBasic Operation of the Menu Menu type Main menu Submenu ExampleTurning the Power Off 2005-01-28 CancelModification of the System Time Time & Date YYYY-MM-DD HhmmssOperation Screen OperationManual Recording Playback of Recorded ImageOperations for Events Playback the recordEvent type Action at an eventPTZ Setup PTZ Select Preset Information Cancellation of alarmCamera Control RS485 Setup Panning/TiltingAuto function Auto Pan, etc PanasonicTo register preset position of cameras To display the camera setting menuZoom FocusControl this Unit with a PC Computer configurationOutlined functions Setup Setting Item DescriptionOperation for Various Settings System Management System MANNtsc Reboot system Reboot System Picture adjustment Picture AdjustDisk information Disk Information Time & date Time & DateRecording & event setup REC & Event Timer recording Timer RECRecord search Search Terminal recording Terminal RECVideo motion detector recording VMD REC VMD Area Setup Area Setup Time Per File 015 Min CancelSetup enabled range 005 Record length Record LengthPTZ setup PTZ Setup Camera setup Camera SetupPreset position information Preset INFORMA- Tion PTZ selection PTZ SelectNetwork setup Network Setup Communication setup CommunicaTCP RS485 setup RS485 Setup Data port setup Data Port SetupSystem log System LOG Report ReportReport System LOG Event LOG Oldest Data Information User level setup User Level Setup User information User InformationEvent log Event LOG Oldest data information Oldest Data InforPassword Password Do you really want to lock keyboard ? CancelData management Data MANAGE- Ment Online user information Online User INFORMA- TionBackup by External HDD Search and PlaybackChannel No Start End Event Only 2004-10-22 2004-10-27Data Management Factory Default Backup 2004-10-10All data will be deleted Will you continue ? Cancel Disk ManagementHDD formatting Disk FormatReturning the Configuration to the Default Settings Recovery of hard disk indexOrdinary screen 9-split screen System Screen ExplanationsScreen in a certain channel Setup Menu Parameters and Initial Setup Values System Management System ManagementRecording & Event Setup REC & Event Timer Recording Timer RECRecording Search Search Terminal Recording Terminal RECPTZ Setup PTZ Setup Camera Setup Camera Setup Communication Setup Communication SetupNetwork Setup Network Setup RS485 Setup RS485 SetupReport Report System Log System LOGEvent Log Event LOG Oldest Data Information Oldest Data InformationUser Information User Information Data Management Data ManagementOperation using the system controller Operation using the WV-CU650Available only during playback Troubleshooting Problem Check item/remedySpecifications Basic SpecificationsGeneral Input/OutputStandard Accessories Table of Recording LengthPage Ns0306-1046 3TR004320BAA