System setup (SYSTEM SETUP)
Item | Descriptions and remarks | Selectable parameters | ||
[Default Setting] | ||||
|
| |||
|
|
|
| |
"Power On Rec." | Recording will automatically start when the power is turned on. | "On/Off" |
| |
|
| "Off" |
| |
|
|
| ||
"Seq. Dwell" | Sequential changeover time intervals. | 02 - 30, 05 | ||
|
|
|
| |
"Video Format" | The video output format is fixed to the NTSC system. Therefore, the user | "NTSC" |
| |
| cannot set the settings. |
|
| |
|
|
|
| |
"Overwrite" | Even when "On" is selected for "Overwrite", recording will not be per- | "On/Off" |
| |
| formed to protect data from overwriting for the days set on "Rec. Reserve" | "On" |
| |
| of "CAMERA SETUP" unless the set days have passed. |
|
| |
|
|
| ||
"Status Display" | It is possible to conceal information such as the channel name that is dis- | "All/Stat/None/Name" | ||
| played on the screen. | "All" |
| |
|
|
|
| |
"Keylock Time" | Even after the lapse of the preset time, the key lock does not function if | 005 - 999 | 600 | |
| recording data is being backed up. |
|
| |
| After the lapse of the preset time counted after the completion of record- |
|
| |
| ing data backup, the key will be automatically locked. |
|
| |
|
|
|
| |
"Keylock Buzz" | When setting is made at "On" and a password is wrongly keyed in three | "On/Off" | "On" | |
| times continuously, the buzzer begins to sound for one minute. |
|
| |
|
|
|
| |
"Alarm Buzz" | Buzzer "On/Off" is set up. | "On/Off" | "Off" | |
|
|
|
| |
"Pre Recording" | The time period for pre recording can differ according to the order of | "On/Off" | "Off" | |
| recording start. The minimum time period is 5 seconds. (Changeable with |
|
| |
| "I Frame Inter.", "Rec. Quality", and "Stream Type") |
|
| |
| When changing this setting, it is necessary to stop recording and discon- |
|
| |
| nect all network connections. |
|
| |
| Note: When Pre Recording is set at "On", the |
|
| |
| may be separated to different data groups. |
|
| |
|
|
| ||
"Rec. Quality" | If settings of "Rec. Quality", "I Frame Inter.", "Stream Type", and "Frame | "SP Fine/Fine/Good/ | ||
| Rate" are changed in the middle of recording, recording will stop and | Normal/Extended" | ||
| then will resume. Then the setting values become effective. | "Normal" |
| |
| If recording is not stopped, the new setting becomes effective after the |
|
| |
| lapse of the time period preset with "RECORD LENGTH". |
|
| |
|
|
|
| |
"I Frame Inter." | Playback is delayed if the setting value for "I Frame Inter." is too high. We | 01 - 15 |
| |
| recommended using a default value. When changing this setting, it is | 04 |
| |
| necessary to stop recording and disconnect the network connections. |
|
| |
| Implement the settings of "I Frame Inter." after the |
|
| |
| has been set at OFF. |
|
| |
|
|
| ||
"Resolution" | Resolution of image data output from the VGA interface | 800 x 600 or 1024 x 768 | ||
|
| [800 x 600] | ||
|
|
|
| |
"Alarm Spot" | When an alarm goes off, the screen of the occurring alarm is displayed in | On/Off | "Off" | |
| the |
|
| |
|
|
|
| |
"Stream Type" | When the setting is made at "VBR", there may be a difference in recording | CBR/VBR |
| |
| length. If the recording time need be in higher preference, the setting | "CBR" |
| |
| should be made at "CBR". If screen changes seem to be extreme, the set- |
|
| |
| ting made at "VBR" is preferable. |
|
| |
|
|
|
| |
"Terminal Input" | N.O.: Alarm is started with a | N.O./N.C. |
| |
| N.C.: Alarm is started with a | "N.O." |
| |
|
|
| ||
"Frame Rate" | The frame rate set at "Full" is 25 frames/second. | "Full, 1/2F, 1/4F, 1/8F, 1/16F" | ||
|
| "Full" |
| |
|
|
|
|
Note: When "Terminal Input" is set at "N.C.", an alarm unit of "N.O." should be connected to the alarm port of this unit. If no con- nections are made, the alarm port will be "N.O." (normally open) and will continue receiving alarm signals at all times.
34